4.10.5 Output terminal function selection (Pr. 190 to Pr. 196)

You can change the functions of the open collector output terminal and relay output terminal.
Parameter
Number
190
RUN terminal
function selection
191
SU terminal function
selection
192
IPF terminal function
selection
193
OL terminal function
selection
194
FU terminal function
selection
195
ABC1 terminal
function selection
196
ABC2 terminal
function selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 175)
...
Specifications differ according to the date assembled. Refer to page 322 to check the SERIAL number.
(1) Output signal list
⋅ You can set the functions of the output terminals.
⋅ Refer to the following table and set the parameters: (0 to 99: Positive logic, 100 to 199: Negative logic)
Setting
Signal
Positive
Negative
Name
Logic
Logic
0
100
RUN
Inverter running
1
101
SU
Up to frequency
Instantaneous power
2
102
IPF
failure/undervoltage
3
103
OL
Overload alarm
Output frequency
4
104
FU
detection
Second output
5
105
FU2
frequency detection
Regenerative brake
7
107
RBP
pre-alarm
Electronic thermal O/
8
108
THP
L relay pre-alarm
10
110
PU
PU operation mode
Inverter operation
11
111
RY
ready
Output current
12
112
Y12
detection
Initial
Name
Value
0
1
Open
collector
2
output
terminal
3
4
99
Relay
output
terminal
9999
Function
Output during operation when the inverter
output frequency rises to or above Pr. 13
Starting frequency.
Output when the output frequency is
*1
reached to the set frequency.
Output at occurrence of an instantaneous
power failure or when undervoltage
protection is activated.
Output while stall prevention function is
activated.
Output when the output frequency reaches
the frequency setting in Pr. 42 (Pr. 43 for
reverse rotation).
Output when the output frequency reaches
the frequency setting in Pr. 50.
Output when 85% of the regenerative brake
duty set in Pr. 70 is reached.
Setting can be made for the 75K or more.
Output when the electronic thermal value
reaches 85% of the trip level.
(Electronic thermal relay function protection
(E.THT/E.THM) actirates, when the value
reached 100%.)
Output when the PU operation mode is
selected.
Output when the reset process is completed
(when the inverter can be started by
switching the start signal on or while it is
running) after powering on the inverter.
Output when the output current is higher
than the Pr. 150 setting for longer than the
time set in Pr. 151.
Function assignment of external
Initial Signal
RUN (inverter running)
SU (up to frequency)
0 to 5, 7, 8, 10 to 19, 25, 26,
45 to 48, 64, 70, 79, 85, 90 to 96, 98,
99, 100 to 105, 107, 108, 110 to
IPF (instantaneous power
failure, undervoltage)
116, 125, 126, 145 to 148, 164,
170, 179, 185, 190 to 196, 198,
199, 9999
OL (overload alarm)
FU (output frequency
detection)
0 to 5, 7, 8, 10 to 19, 25, 26, 45 to
ALM (fault output)
48, 64, 70, 79, 85, 90, 91, 94 to 96,
98, 99, 100 to 105, 107, 108, 110
to 116, 125, 126, 145 to 148, 164,
170, 179, 185, 190, 191, 194 to
No function
196, 198, 199, 9999
Operation
terminal and control
Setting Range
Related
Refer
Parameters
to Page
123
Pr. 41
125
Pr. 57
141
Pr. 22, Pr. 23,
Pr. 66, Pr. 148,
77
Pr. 149, Pr. 154
Pr. 42, Pr. 43
125
Pr. 50
125
Pr. 70
107
Pr. 9
103
Pr. 79
177
123
Pr. 150, Pr. 151
126
121
4