Mitsubishi Electric FR-F720-0.75K to 110K Instruction Manual page 132

Table of Contents

Advertisement

Setting
Signal
Positive
Negative
Name
Logic
Logic
99
199
ALM
Fault output
9999
No function
*1
Note that when the frequency setting is varied using an analog signal or
frequency) signal may alternate on and off depending on that varying speed and the timing of the varying speed due to acceleration/
deceleration time setting. (The output will not alternate on and off when the acceleration/deceleration time setting is "0s".)
*2
When a power supply reset is performed, the fault output 2 signal (ALM2) turns off as soon as the power supply switches off.
REMARKS
⋅ The same function may be set to more than one terminal.
⋅ When the function is executed, the terminal conducts at the setting of any of "0" to "99", and does not conduct at the setting of
any of "100" to "199".
⋅ When Pr. 76 Fault code output selection = "1", the output signals of the terminals SU, IPF, OL and FU are switched as set in Pr. 76.
(When an inverter fault occurs, the signal output is switched to the fault code output.)
⋅ The output assignment of the terminal RUN and fault output relay are as set above regardless of Pr. 76.
CAUTION
⋅ Changing the terminal assignment using Pr. 190 to Pr. 196 (output terminal function selection) may affect the other functions.
Please make setting after confirming the function of each terminal.
⋅ Do not assign signals which repeat frequent ON/OFF to A1, B1, C1, A2, B2, C2. Otherwise, the life of the relay contact decreases.
(2) Inverter operation ready signal (RY signal) and inverter running signal (RUN, RUN3 signal)
Power
ON
supply
ON
STF
ON
RH
Pr. 13
Starting
frequency
Reset
processing
ON
RY
ON
RUN
ON
RUN3
Inverter
Start
Start
Status
Signal is
Signal is
OFF
ON
(during
(during
Output
stop)
stop)
Signal
RY
ON
ON
RUN
OFF
OFF
RUN3
OFF
ON
*1
This signal turns off during power failure or undervoltage.
REMARKS
⋅ Run signal is assigned to the terminal RUN in the initial setting.
Function
Output when the fault occurs. The signal
output is stopped when the fault is reset.
⋅ When the inverter is ready to operate, the output of the operation
ready signal (RY) is on. It is also on during inverter running.
⋅ When the output frequency of the inverter rises to or above
OFF
Pr. 13 Starting frequency, the output of the inverter running
OFF
signal (RUN) is turned on. During an inverter stop or DC
injection brake operation, the output is off.
⋅ The output of the RUN3 signal is on when the inverter running
and start signals are on.
DC injection brake
operation point
(For the RUN3 signal, output is on if the starting command is
DC injection
on even when a fault occurs or the MRS signal is on.
brake
When using the RY, RUN and RUN3 signals, assign functions to
operation
Pr. 190 to Pr. 196 (output terminal selection function) referring to the
Time
table below.
OFF
OFF
OFF
At Fault Occurrence or
Start
Signal is
Under DC
ON
Injection
(during
Brake
Start signal
running)
ON
ON
ON
OFF
ON
ON
Function assignment of external
Operation
of the operation panel (FR-DU07), the output of the SU (up to
Pr. 190 to Pr. 196 Setting
Output
Signal
Positive logic
Negative logic
RY
11
RUN
0
RUN3
45
Instantaneous Power Failure
MRS Signal is on
(output shutoff)
Start signal
Start signal
is ON
is OFF
is ON
OFF
OFF
ON
OFF
ON
terminal and control
Related
Refer
Parameters
to Page
124
111
100
145
Automatic Restart after
Coasting
Restarting
Start signal
is OFF
ON
ON
*1
OFF
ON
OFF
ON
123
4