Param-
Func-
eter
tion
Number
57
Restart coasting time
58
Restart cushion time
Remote setting function
59
selection
Shortest acceleration/
60
deceleration mode
61
Reference current
Reference current for
62
acceleration
Reference current for
63
deceleration
65
Retry selection
Stall prevention operation
66
level reduction starting
frequency (Note 6)
Number of retries at alarm
67
occurrence
68
Retry waiting time
69
Retry count display erasure
Special regenerative brake
70
duty
71
Applied motor (Note 6)
72
PWM frequency selection
73
0-5V/0-10V selection
74
Filter time constant
Reset selection/
75
disconnected PU detection/
PU stop selection
Parameter write disable
77
selection
Reverse rotation
78
prevention selection
Operation mode selection
79
(Note 6)
80
Motor capacity (Note 6)
82
Motor excitation current
Rated motor voltage
83
(Note 6)
Rated motor frequency
84
(Note 6)
90
Motor constant (R1)
Auto-tuning setting/status
96
(Note 6)
Setting
Name
Range
0 to 5 s, 9999
0 to 60 s
0, 1, 2
0, 1, 2, 11, 12
0 to 500A,
9999
0 to 200%,
9999
0 to 200%,
9999
0, 1, 2, 3
0 to 400Hz
0 to 10,
101 to 110
0.1 to 360 s
0
0 to 30%
0, 1, 3, 5, 6,
13, 15, 16, 23,
100, 101, 103,
105, 106, 113,
115, 116, 123,
0 to 15
0, 1
0 to 8
0 to 3,
14 to 17
0, 1, 2
0, 1, 2
0 to 4, 6 to 8
0.1 to 7.5kW,
9999 (Note 8)
0 to 500A,
9999
0 to 1000V
50 to 120Hz 0.01Hz (Note 3)
0 to 50Ω,
9999
0, 1
78
PARAMETERS
Minimum
Factory
Setting
Setting
Increments
0.1s
9999
0.1s
1.0 s
1
0
1
0
0.01A
9999
1%
9999
1%
9999
1
0
0.01Hz (Note 3)
60Hz
1
0
0.1s
1 s
1
0
0.1%
0%
1
0
1
1
1
0
1
1
1
14
1
0
1
0
1
1
0.01kW
9999
0.01A
9999
200V/
0.1V
400V
60Hz
0.001Ω
9999
1
0
Custo-
Refer
mer
To:
Setting
108
108
110
113
113
113
113
115
96
115
115
115
100
117
118
120
120
121
123
124
124
128
129
129
129
129
129

Hide quick links: