Download  Print this page

Retry Function (pr. 65, Pr. 67 To Pr. 69) - Mitsubishi Electric FR-E520 Instruction Manual

Transistorized inverter.
Hide thumbs

Advertisement

4.2.25 Retry function (Pr. 65, Pr. 67 to Pr. 69)

Pr. 65 "retry selection"
Pr. 67 "number of retries at alarm occurrence"
Pr. 68 "retry waiting time"
Pr. 69 "retry count display erasure"
When any protective function (major fault) is activated and the inverter stops its output,
the inverter itself resets automatically and performs retries. You can select whether retry
is made or not, alarms reset for retry, number of retries made, and waiting time.
Parameter
Number
65
67
68
69
<Setting>
Use Pr. 65 to select the protective functions (major faults) which execute retry.
Errors Reset for
Retry
Display
E.OC1
E.OC2
E.OC3
E.OV1
E.OV2
E.OV3
E.THM
E.THT
E.FIN
E. BE
E. GF
E. LF
E.OHT
E.OLT
E.OPT
E. PE
E.PUE
E.RET
E.CPU
E.P24
E. 3
E. 6
E. 7
Note: ! indicates the retry items selected.