Download  Print this page

Jog Operation (pr. 15, Pr. 16) - Mitsubishi Electric FR-E520 Instruction Manual

Transistorized inverter.
Hide thumbs

Advertisement

4.2.10 Jog operation (Pr. 15, Pr. 16)

Pr. 15 "jog frequency"
Pr. 16 "jog acceleration/
deceleration time"
Jog operation can be started and stopped by selecting the jog mode from the operation
panel and pressing and releasing the
• Set the frequency and acceleration/deceleration time for jog operation.
Parameter
Factory
Number
Setting
15
5Hz
16
0.5s
Output frequency (Hz)
Jog frequency
Pr.15
setting range
Note: 1. In S-shaped acceleration/deceleration pattern A, the acceleration/
deceleration time is the period of time required to reach Pr. 3 "base
frequency", not Pr. 20.
2. The acceleration time and deceleration time cannot be set separately for jog
operation.
3. The value set in Pr. 15 "jog frequency" should be equal to or greater than
the Pr. 13 "starting frequency" setting.
# # # # Refer to Pr. 1, Pr. 2.
Pr. 18
# # # # Refer to Pr. 3.
Pr. 19
# # # # Refer to Pr. 7, Pr. 8.
Pr. 20, Pr. 21
key (
RUN
Setting
Range
0 to 400Hz
0 to 3600 s
0 to 360 s
Pr.20
Forward
rotation
Pr.16
ON
key
FWD
key
REV
95
PARAMETERS
Related parameters
Pr. 20 "acceleration/deceleration
reference frequency"
Pr. 21 "acceleration/deceleration
time increments"
,
key).
FWD
REV
Remarks
When Pr. 21 = 0
When Pr. 21 = 1
Reverse
Time
rotation
ON