2)Set "1" (PU operation mode) in Pr. 79 "operation mode selection".
Example: To change the external operation mode (Pr. 79 = 2) to the PU operation
mode (Pr. 79 = 1)
Using the
key,
MODE
choose the "parameter
setting mode" as in 1).
Parameter setting mode
EXT
MODE
SET
REV
STOP
FWD
RESET
MIN
Current setting
SET
Flicker
Most significant
digit flickers
SET
MAX
Setting change
Press for
1.5s
SET
Setting write
180
Middle digit flickers
SET
× 7 times
0 to 9
If
appears, make sure that the forward
rotation (STF) or reverse rotation (STR) signal
connected to the control terminal is not on.
If it is on, turn it off.
"1" (PU operation mode) has been set in Pr. 79.
If
appears, you did not press the
key for 1.5s when writing the setting.
Restart the procedure from the beginning.
Press the
key once, press the
restart the setting from the beginning.
PARAMETERS
Least significant
digit flickers
× 9 times
SET
0 to 9
SET
key, and
SET