! ! ! ! Using the connection cable for operation
1) Remove the operation panel.
2) Fit the rear cover option FR-E5P to the back surface of the operation panel.
3) Securely plug one end of the connection cable into the PU connector of the
inverter and the other end into the adaptor of the FR-E5P option to connect it to
the operation panel. (For the connection cable of the FR-E5P, refer to page 29.)
! ! ! ! Mounting the operation panel on an enclosure
When you open the operation panel front cover, the screw mounting guides for
fixing the operation panel to an enclosure appear on the top left and bottom right.
Remove the operation panel, fit the rear cover of the FR-E5P option, drill holes in
the operation panel mounting guides, and securely mount the operation panel on
the enclosure with screws.
1.3.5

Removal of the operation panel front cover

1)Open the operation panel front cover to 90 degrees.
2)Pull out the operation panel front cover to the left to remove it.
90 degrees
PU connector
(RS-485 cable specifications)