1.3.4

Removal and reinstallation of the operation panel

To ensure safety, remove and reinstall the operation panel after switching power off.
The charging area and control printed board are exposed on the rear surface of the
operation panel. When removing the operation panel, always fit the rear cover option FR-
E5P. Never touch the control printed board because touching it can cause the inverter to fail
! ! ! ! Removal
Hold down the portion A indicated by the arrow and lift the right hand side using
the portion B indicated by the arrow as a support, and pull out the operation panel
to the right.
)
(If the above procedure is not used for removal, the internal connector may be
damaged by the force applied.)
! ! ! ! Reinstallation
Insert the mounting hook (left hand side) of the operation panel into the mounting
position of the inverter and push in the right hand side mounting hook to install the
operation panel.
Mounting position
1)
B
2)
A
Operation panel
Hook
3)
A
2)