AGC Group

001 FAST DELAY
Function: Sets the delay time for the AGC FAST mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 500 msec
002 MID DELAY
Function: Sets the delay time for the AGC MID mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 1000 msec
003 SLOW DELAY
Function: Sets the delay time for the AGC SLOW mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 4000 msec
004 AGC SLOPE
Function: Select the gain curve of the AGC amplifier.
Available Values: NORMAL/SLOPE
Default Setting: NORMAL
NORMAL: The AGC output level will follow a linear
response to the antenna input level, while
AGC is activated.
SLOPE:
The AGC output level will increase at 1/10
the rate of the antenna input level, while
AGC is activated.

DISPLAY Group

005 MY CALL
Function: Programs your Call Sign.
Available Values: Max 12 characters
Default Setting: FTDX3000
006 MY CALL TIME
Function: Programs the display period of your Call Sign.
Available Values: OFF ~ 5 sec
Default Setting: 1 sec
007 DIMMER VFO
Function: Setting of the VFO-A display brightness level.
Available Values: 0 ~ 15
Default Setting: 8
FT
3000 O
DX
peraTing
M
anual
M
008 DIMMER BACKLIGHT
Function: Sets the keypad illumination level.
Available Values: 0 ~ 15
Default Setting: 8
Adjusts the illumination level of the six keys located on
the left side of the LCD display. You may observe the
effects of the changes as you adjust the level setting. The
higher the setting, the brighter the illumination becomes.
009 DIMMER TFT
Function: Setting of the TFT display brightness level.
Available Values: 0 ~ 15
Default Setting: 8
010 BAR DISPLAY SELECT
Function: Selects one of three parameters to be viewed
on the Tuning Offset Indicator.
Available Values: CLAR/CW TUNE/uTUNE
Default Setting: CW TUNE
CLAR:
Displays relative clarifier offset.
CW TUNE: Displays relative tuning offset between the
incoming signal and transmitted frequency
while in CW operation.
uTUNE:
Displays the peak position of the optional
u -TUNE filter.
011 METER TYPE SELECT
Function: Selects the meter display type.
Available Values: ANALOG/BAR
Default Setting: ANALOG
ANALOG: Displays relative clarifier offset.
BAR:
Displays relative tuning offset between the
incoming signal and transmitted frequency
while in CW operation.
012 BAR MTR PEAK HOLD
Function: Selects the peak hold time of the BAR meter.
Available Values: OFF/0.5/1.0/2.0 sec
Default Setting: OFF
013 ROTATOR START UP
Function: Selects the starting point of your rotator
controller's indicator needle.
Available Values: 0/90/180/270°
Default Setting: 0°
Advice: If the optional Antenna Rotator is not
connected, this adjustment has no effect.
014 ROTATOR OFFSET ADJ
Function: Adjusts the indicator needle precisely to the
starting point set in menu item "013 ROTATOR START
UP" .
Available Values: -30° ~ 0° (2°/step)
Default Setting: 0°
Advice: If the optional Antenna Rotator is not
connected, this adjustment has no effect.