Cat Rate; Mic Scan; Mic Scan Resume; Cat Rts - Yaesu FT DX 3000 Operating Manual

Hf/50 mhz transceiver
Hide thumbs Also See for FT DX 3000:
Table of Contents

Advertisement

M
M
enu
ODe
036 RF SQL VR
Function: Selects the operation mode of the RF/SQL
knob.
Available Values: RF/SQL
Default Setting: RF
037 CAT SELECT
Function: Selects the CAT jack to be used.
Available Values: RS232C/USB
Default Setting: USB

038 CAT RATE

Function: Sets the transceiver computer-interface
circuitry for the CAT baud rate to be used.
Available Values: 4800/9600/19200/38400 bps
Default Setting: 4800 bps
039 CAT TIME OUT TIMER
Function: Sets the Time-Out Timer countdown time for
a CAT command input.
Available Values: 10/100/1000/3000 msec
Default Setting: 10 msec
The Time-Out Timer shuts off the CAT data input after a
continuous transmission of the programmed time.

040 CAT RTS

Function: Enables/Disables the RTS port of the CAT
jack.
Available Values: ENABLE/DISABLE
Default Setting: ENABLE
041 GENE MEM GRP
Function: Enables/Disables Memory Group Operation.
Available Values: ENABLE/DISABLE
Default Setting: DISABLE

042 QUICK SPLIT FREQ

Function: Selects the tuning offset for the Quick Split
feature.
Available Values: -20 ~ 0 ~ +20 kHz (1 kHz Step)
Default Setting: +5 kHz
043 TX TIME OUT TIMER
Function: Sets the Time-Out Timer countdown time.
Available Values: OFF/1 ~ 30 min
Default Setting: OFF
The Time-Out Timer shuts off the transmitter after
continuous transmission of the programmed time.
Page 116
044 uTUNE DIAL STEP
Function: Selects the µ -TUNE mode.
Available Values: DIAL STEP-1/DIAL STEP-2
Default Setting: DIAL STEP-1
DIAL STEP-1: Activates the µ -TUNE system using
"COARSE" steps of the [CLAR/VFO-B]
knob (2 steps/click) on the 7 MHz and
lower amateur bands. On the 10/14 MHz
bands, "FINE" [CLAR/VFO-B] knob
steps will be used (1 step/click).
DIAL STEP-2: Activates the µ -TUNE system using
"FINE" steps of the [CLAR/VFO-B]
knob (1 step/click) on the 14 MHz and
lower amateur bands.
Advice: If an optional RF µ Tuning Kit is not connected,
this adjustment has no effect.

045 MIC SCAN

Function: Enables/disables scanning access via the
microphone [UP]/[DWN] keys.
Available Values: ENABLE/DISABLE
Default Setting: ENABLE

046 MIC SCAN RESUME

Function: Selects the Scan Resume mode.
Available Values: PAUSE/TIME
Default Setting: TIME
PAUSE: T h e s c a n n e r w i l l h o l d u n t i l t h e s i g n a l
disappears, then will resume after one second.
TIME: The scanner will hold for five seconds, then
resume whether or not the other station is still
transmitting.
047 FREQ ADJ
Function: Adjusts the reference oscillator.
Available Values: - 25 ~ 0 ~ +25
Default Setting: 0
To calibrate the frequency of your radio, you will need
a frequency counter or set your receiver to one of the
time standard frequencies such as WWV or WWVH.
The following example describes a calibration method
while receiving the WWVH time standard frequency in
Hawaii.
1. Turn off both RX CLAR and TX CLAR function,
before adjustment.
2. Tune the radio to 15,000.00 MHz with CW-USB
mode, then adjust the AF knob to comfortable
listening level.
3. Enter Set Menu Item "047 FREQ ADJ", and then
adjust the [ CLAR/VFO-B ] knob so that the BAR
display is illumination in the center on the meter.
FT
3000 O
DX
M
peraTing
anual

Advertisement

Table of Contents
loading

Table of Contents