AGC G
001 AGc FST DLY
Function: Sets the delay time for the AGC FAST mode of
the Main band (VFO-A) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 300 msec
002 AGc FST HLD
Function: Sets the hang time of the AGC peak voltage for
the AGC FAST mode of the Main band (VFO-A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
003 AGc MID DLY
Function: Sets the delay time for the AGC MID mode of
the Main band (VFO-A) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 700 msec
004 AGc MID HLD
Function: Sets the hang time of the AGC peak voltage for
the AGC MID mode of the Main band (VFO-A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
005 AGc SLW DLY
Function: Sets the delay time for the AGC SLOW mode of
the Main band (VFO-A) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 2000 msec
006 AGc SLW HLD
Function: Sets the hang time of the AGC peak voltage for
the AGC SLOW mode of the Main band (VFO-A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
Page 116
ROUP
DISPLAY G
007 diSP COLOR
Function: Selects the Display color when the optional Data
Management Unit (DMU-2000) is connected.
Available Values: bL1 / bL2 / bL3 / ub1 / ub2
bL1: COOL BLUE
bL2: CONTRAST BLUE
bL3: FLASH WHITE
ub1: CONTRAST UMBER
ub2: UMBER
Default Setting: bL1 (COOL BLUE)
A
:
DVICE
If the optional DMU-2000 Data Management Unit is not
connected, this adjustment has no effect.
008 diSP DIM MTR
Function: Setting of the meter brightness level when
"DIM" is selected.
Available Values: 0 ~ 15
Default Setting: 7
009 diSP DIM VFD
Function: Setting of the frequency display brightness level
when "DIM" is selected.
Available Values: 0 ~ 7
Default Setting: 4
010 diSP BAR SEL
Function: Selects one of three parameters to be viewed
on the Tuning Offset Indicator.
Available Values: CLAr / C-tn / u-tn
Default Setting: C-tn
CLAr: Displays relative clarifier offset.
C-tu: Displays relative CW tuning offset between the
incoming signal and transmitted frequency.
u-tn: Displays the peak position of the VRF or μ-
TUNE filter.
N
:
OTE
The μ-TUNE filter is an option.
011 diSP PK HLD
Function: Selects the peak hold time of the Sub (VFO-B)
receiver's S-meter.
Available Values: OFF / 0.5 / 1.0 / 2.0 sec
Default Setting: OFF
012 diSP RTR STU
Function: Selects the starting point of your rotator
controller's indicator needle.
Available Values: 0 / 90 / 180 / 270°
Default Setting: 0°
013 diSP RTR ADJ
Function: Adjusts the indicator needle precisely to the
starting point set in menu item "012 diSP RTR STU."
Available Values: –30 ~ 0°
Default Setting: 0°