Agc Group; Display Group - Yaesu FT dx 1200 Operating Manual

Hf/50 mhz transceiver
Hide thumbs Also See for FT dx 1200:
Table of Contents

Advertisement

m
m
enu
oDe
Agc g
001 FAST DELAY
Function: Sets the delay time for the AGC FAST mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 500 msec
002 MID DELAY
Function: Sets the delay time for the AGC MID mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 1000 msec
003 SLOW DELAY
Function: Sets the delay time for the AGC SLOW mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 4000 msec
004 AGC SLOPE
Function: Select the gain curve of the AGC amplifier.
Available Values: NORMAL/SLOPE
Default Setting: NORMAL
NORMAL: The AGC output level will follow a linear
response to the antenna input level, while
AGC is activated.
SLOPE:
The AGC output level will increase at 1/10
the rate of the antenna input level, while
AGC is activated.
diSplAy g
005 MY CALL
Function: Programs your Call Sign.
Available Values: Max 12 characters
Default Setting: FTDX1200
006 MY CALL TIME
Function: Programs the display period of your Call Sign.
Available Values: OFF ~ 5 sec
Default Setting: 1 sec
007 VFO COLOR
Function: Selects the VFO-A frequency background
color.
Available Values: BLUE / SKY BLUE / GREEN /
PURPLE / RED / ORANGE / GRAY / BLACK
Default Setting: BLUE
Page 112
roup
AGC start
roup
008 TFT LAYOUT
Function: Set the positions of the frequency display and
meter display.
Available Values: TYPE1 / TYPE2
Default Setting: TYPE1
TYPE1: Displays the frequency display at the top of
the TFT display.
TYPE2: Displays the frequency display below the S/
PO meter and the DSP display.
009 DIMMER LED
Function: Sets the indicator illumination level.
Available Values: 1 / 2
Default Setting: 2
Adjusts the illumination level of the indicator located
on the above of the Main Tuning Dial knob. You may
observe the effects of the changes as you adjust the
level setting. The higher the setting, the brighter the
illumination becomes.
010 DIMMER TFT
Function: Setting of the TFT display brightness level.
Available Values: 0 ~ 15
Default Setting: 8
011 BAR DISPLAY SELECT
Function: Selects one of three parameters to be viewed
on the Tuning Offset Indicator.
Available Values: CLAR/CW TUNE/uTUNE
Default Setting: CW TUNE
CLAR:
Displays relative clarifier offset.
CW TUNE: Displays relative tuning offset between the
incoming signal and transmitted frequency
while in CW operation.
uTUNE:
Displays the peak position of the optional
u -TUNE filter.
012 METER TYPE SELECT
Function: Selects the meter display type.
Available Values: ANALOG/BAR
Default Setting: ANALOG
ANALOG: Displays relative clarifier offset.
BAR:
Displays relative tuning offset between the
incoming signal and transmitted frequency
while in CW operation.
013 BAR MTR PEAK HOLD
Function: Selects the peak hold time of the BAR meter.
Available Values: OFF/0.5/1.0/2.0 sec
Default Setting: OFF
014 ROTATOR START UP
Function: Selects the starting point of your rotator
controller's indicator needle.
Available Values: 0/90/180/270°
Default Setting: 0°
Advice: If the optional Antenna Rotator is not
connected, this adjustment has no effect.
FT
1200 O
DX
M
peraTing
anual

Advertisement

Table of Contents
loading

Table of Contents