Service Parts Disassembly
Fuser Assembly (PL3.0.61)
8-10
3. To remove the Shaft, first release the locker and slide the Shaft from left to
right, then lift the notch attached to the Cam so that it's released from the
Shaft. Then release the Bush from the Shaft and remove the Shaft from
the Duplex Guide Housing, as shown below.
1. Open the face up cover and open the fuser output guide.
2. Remove the four screws securing the Fuser Assembly, then pull the Fuser
Assembly out of the frame.
2
3
Shaft
Cam
Bush
1
Lock
Phaser 3300MFP Service Manual
4
s3300mfp-122