6-7 Fuser Assembly
1. Before you remove the Fuser assembly, you
should remove:
- Side cover assembly (see page 6-9).
2. Unplug the connector.
3. Remove the four screws and take out the fuser
assembly.
WorkCentre Pro 412
Launch Issue
4. Remove the four screws and take out the ther-
mostat.
5. Remove the two screws and take out the heat
roller.
6. Remove the halogen lamp from the heat roller.
August 2001
Disassembly and Reassembly
6-9