Acceleration/Deceleration Pattern; External Frequency Adjustment Function (Fi) - Omron 3G3JX User Manual

Sysdrive jx series compact simplified inverters
Hide thumbs Also See for 3G3JX:
Table of Contents

Advertisement

4-2 Function Mode

Acceleration/Deceleration Pattern

This function is used when smooth acceleration/deceleration is needed.
Parameter No.
A097
A098
•Acceleration/deceleration pattern can be set according to each system.
4
Parameter No.
A097
(Acceleration)
A098
(Deceleration)
Accelerates/Decelerates linearly before reaching
Description

External Frequency Adjustment Function (FI)

Parameter No.
A101
A102
A103
A104
A105
Related functions
For each item, refer to "External Frequency (Voltage/Current) Adjustment" (page 4-10).
4-25
Function name
Acceleration pattern
00: Line
selection
01: S-shape curve
Deceleration pattern
00: Line
selection
01: S-shape curve
00
Line
Time
Time
the set output frequency value.
Function name
FI start frequency
0.00 to 400.0
FI end frequency
0.00 to 400.0
FI start ratio
0. to 100.
FI end ratio
0. to 100.
00: External start selection
FI start selection
01: 0 Hz
Data
Set value
Helps prevent the collapse of cargo on the
elevating machine or conveyor.
Data
A005, A011 to A015, A016, A151 to A155, AT input
Default setting
Unit
00
00
01
S-shape curve
Time
Time
Default setting
Unit
0.0
Hz
0.0
Hz
0.
%
100.
%
01

Hide quick links:

Advertisement

Table of Contents
loading