Parameter
Function name
No.
Overload limit
b021
selection
*2nd overload limit
b221
selection
Overload limit
b022
level
*2nd overload limit
b222
level
Overload limit
b023
parameter
*2nd overload limit
b223
parameter
Overload limit
b028
source selection
*2nd overload limit
b228
source selection
Deceleration rate
constant at
b029
frequency pull-in
restart
Frequency pull-in
b030
restart level
b031
Soft lock selection
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
Monitor or data range
(Digital Operator)
00: Disabled
01: Enabled in acceleration/constant speed
operation
02: Enabled in constant speed operation
0..1 × Rated current to 1.5 × Rated current
0.1 to 3000.0
00: b022, b222 set values
01: Input terminal FV
0.1 to 3000.0
0.2 × Rated current to 2.0 × Rated current
00: Data other than b031 cannot be changed
when terminal SFT is ON.
01: Data other than b031 and the specified
frequency parameter cannot be changed
when terminal SFT is ON.
02: Data other than b031 cannot be changed.
03: Data other than b031 and the specified
frequency parameter cannot be changed.
10: Data other than parameters changeable
during operation cannot be changed.
Appendix-1 Parameter List
Changes
Default
during
Unit
setting
operation
01
No
01
1.5 ×
Rated
current
No
A
1.5 ×
Rated
current
1.0
No
s
1.0
00
No
00
0.5
No
s
Rated
No
A
current
01
No
App-10
Set
value