Omron 3G3JX User Manual page 241

Sysdrive jx series compact simplified inverters
Hide thumbs Also See for 3G3JX:
Table of Contents

Advertisement

Parameter
Name
No.
d102
DC voltage monitor
Electronic thermal
d104
monitor
Output frequency
F001
setting/monitor
F002
Acceleration time 1
*2nd acceleration
F202
time 1
F003
Deceleration time 1
*2nd deceleration
F203
time 1
Operator rotation
F004
direction selection
* 2nd function is displayed when SET(08) is allocated to one of from C001 to C005.
Extended function mode
Parameter
Function name
No.
Frequency
A001
reference
selection
*2nd frequency
A201
reference
selection
RUN command
A002
selection
*2nd RUN
A202
command
selection
A003
Base frequency
*2nd base
A203
frequency
Maximum
A004
frequency
*2nd maximum
A204
frequency
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
Monitor or data range
(Digital Operator)
0.0 to 999.9
0.0 to 100.0
Starting frequency to 1st or 2nd max.
frequency
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
00: Forward
01: Reverse
Monitor or data range
(Digital Operator)
00: Digital Operator (FREQ adjuster)
01: Terminal
02: Digital Operator (F001)
03: ModBus communication
10: Frequency operation result
01: Terminal
02: Digital Operator
03: ModBus communication
30. to Max. frequency [A004]
30. to Max. frequency [A204]
30. to 400.
Appendix-1 Parameter List
Changes
Default
during
Unit
setting
operation
V
%
Yes
Hz
10.0
Yes
s
10.0
Yes
s
10.0
Yes
s
10.0
Yes
s
00
No
Changes
Default
during
Unit
setting
operation
00
No
00
No
02
No
02
No
60.
No
Hz
60.
60.
No
Hz
60.
App-2
Set
value
Set
value

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents