4-2 Function Mode
Register
Function name
No.
1007h
Multi-function input monitor
1008h
Multi-function output monitor
1009h
Output frequency monitor
4
(after conversion)
100Ah
100Ch
Output voltage monitor
100Eh
Total RUN time
100Fh
1010h
Power ON time monitor
1011h
116Ah
Fin temperature monitor
0011h
Fault frequency monitor
116Ch
DC voltage monitor
116Dh
Electronic thermal monitor
0012h
0014h
0016h
0017h
Fault monitor 1
0018h
0019h
001Ah
001Bh
001Ch
001Eh
0020h
0021h
Fault monitor 2
0022h
0023h
0024h
0025h
4-93
Parameter
R/W
No.
Function
0 to 63
d005
R
Multi-function input status, Bit 0 = [1] to
Bit 4 = [5]
0 to 7
Multi-function output status,
d006
R
Bit 0 = [P1]
Bit 1 = Not used.
Bit 2 = [MA]
d007
(MSB)
R
0 to 3996000
d007
(LSB)
d013
R
0 to 20000
d016
(MSB)
R
0 to 999999
d016
(LSB)
d017
(MSB)
R
0 to 999999
d017
(LSB)
d018
R
0 to 2000
d080
R
0 to 65535
d102
R
0 to 9999
d104
R
0 to 1000
R
Trip monitor 1: Factor code
R
Trip monitor 1: Frequency
R
Trip monitor 1: Current
R
Trip monitor 1: Voltage
d081
R
Trip monitor 1: Run time (MSB)
R
Trip monitor 1: Run time (LSB)
R
Trip monitor 1: ON time (MSB)
R
Trip monitor 1: ON time (LSB)
R
Trip monitor 2: Factor code
R
Trip monitor 2: Frequency
R
Trip monitor 2: Current
R
Trip monitor 2: Voltage
d082
R
Trip monitor 2: Run time (MSB)
R
Trip monitor 2: Run time (LSB)
R
Trip monitor 2: ON time (MSB)
R
Trip monitor 2: ON time (LSB)
Monitor or data range
Resolution
0.01
0.01 [%]
1 [h]
1 [h]
0.1 [°C]
0.1 [V]
0.1 [%]
0.1 [Hz]
0.1 [A]
1. [V]
1. [h]
1. [h]
0.1 [Hz]
0.1 [A]
1. [V]
1. [h]
1. [h]