Omron 3G3JX User Manual page 188

Sysdrive jx series compact simplified inverters
Hide thumbs Also See for 3G3JX:
Table of Contents

Advertisement

4-2 Function Mode
Register
Function name
No.
1124h
Overload warning level
153Ah
2nd overload warning level
Arrival frequency during
1126h
acceleration
Arrival frequency during
1128h
deceleration
PID deviation excessive
1129h
level
4
112Eh
PID FB upper limit
112Fh
PID FB lower limit
1137h
Operator/ModBus selection
Communication speed
1138h
selection
(Baud rate selection)
Communication station No.
1139h
selection
Communication parity
113Bh
selection
Communication stop bit
113Ch
selection
Communication error
113Dh
selection
Communication error
113Eh
timeout
113Fh
Communication wait time
1141h
FV adjustment
1142h
FI adjustment
1145h
AM offset adjustment
Not used
1149h
UP/DWN selection
114Ah
Reset selection
Logic operation function A
1150h
input
Logic operation function B
1151h
input
1152h
Logic operator selection
4-103
Parameter
R/W
No.
Function
C041
R/W
0 to 20000
Set to10000 at rated current
C241
R/W
C042
R/W
0 to 4000
C043
R/W
0 to 4000
C044
R/W
0 to 1000
C052
R/W
0 to 1000
C053
R/W
0 to 1000
C070
C071
C072
Do not change through ModBus
C074
communication. For setting, refer to
"ModBus Setting" (4-78).
C075
C076
C077
C078
C081
R/W
0 to 2000
C082
R/W
0 to 2000
C086
R/W
0 to 100
C091
Do not change.
C101
R/W
00: OFF/01: ON
00: Trip reset at power-on
01: Trip reset when the power is OFF
C102
R/W
02: Enabled only during trip (Reset when
the power is ON.)
C141
R/W
00: RUN/01: FA1/02: FA2/03: OL/04:
OD/05: AL/06: Dc/07: FBV/08: NDc/10:
ODc(Do not use.)/43: LOC
C142
R/W
C143
R/W
00: AND/01: OR/02: XOR
Monitor or data range
Resolution
0.01 [%]
0.1 [Hz]
0.1 [Hz]
0.1 [%]
0.1 [%]
0.1 [%]
0.1 [%]
0.1 [%]
0.1 [V]