3-4 Operation Procedure (Example: Factory Default)

Setting Functions

•Switch the method of the RUN command. (Digital Operator → Control terminal block)
•To switch the method of the RUN command from the Digital Operator (factory default) to the control
terminal block, you need to change the frequency reference selection (A001) from the Digital
Operator (02) to the terminal (01).
3
3-13
1. Display the extended function mode (as "A---").
ak-k-k-
Press
2. The code of the extended function mode is displayed (as "A001").
ak0k0k1
Press
("A002" is displayed.)
ak0k0k2
Press
3. The setting of the extended function mode is displayed (setting in "A002").
0k2
Press
(Continued to the next page)
•To display "A---", follow the indication method
described in "Displaying the Monitor Mode,
Basic Function Mode, and Extended Function
Mode" (page 3-11).
•By default, the RUN command LED indicator will
light up as the RUN command selection is set to
the Digital Operator.
•"02 (Digital Operator)" (default setting) is
displayed in the RUN command selection
(A002).
•The PROGRAM (PRG) LED indicator lights up
while the extended function mode setting is
displayed.