Parameter
Function name
No.
A101
FI start frequency
A102
FI end frequency
A103
FI start ratio
A104
FI end ratio
A105
FI start selection
Operation
A141
frequency input A
setting
Operation
A142
frequency input B
setting
A143
Operator selection
Frequency
A145
addition amount
Frequency
A146
addition direction
A151
VR start frequency 0.0 to 400.0
A152
VR end frequency
A153
VR start ratio
A154
VR end ratio
A155
VR start selection
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
Monitor or data range
(Digital Operator)
0.0 to 400.0
0.0 to 400.0
0. to 100.
0. to 100.
00: Use FI start frequency [A101]
01: 0 Hz start
00: Digital Operator (F001)
01: Digital Operator (FREQ adjuster)
02: Input FV
03: Input FI
04: RS485 communication
00: Addition (A + B)
01: Subtraction (A - B)
02: Multiplication (A × B)
0.0 to 400.0
00: Adds A145 value to output frequency
01: Subtract A145 value from output
frequency
0.0 to 400.0
0. to 100.
0. to 100.
00: Use VR start frequency [A151]
01: 0 Hz start
Appendix-1 Parameter List
Changes
Default
during
Unit
setting
operation
0.0
No
Hz
0.0
No
Hz
0.
No
%
100.
No
%
01
No
01
No
02
No
00
No
0.0
Yes
Hz
00
No
0.0
No
Hz
0.0
No
Hz
0.
No
%
100.
No
%
01
No
App-8