2-step Acceleration/Deceleration Function

This function changes the acceleration/deceleration time during such operations.
Parameter No.
Function name
A092
Acceleration time 2
*
A292
2nd acceleration time 2
A093
Deceleration time 2
*
A293
2nd deceleration time 2
2-step acceleration/
A094
deceleration selection
2nd 2-step acceleration/
*
A294
deceleration selection
2-step acceleration
A095
frequency
2nd 2-step acceleration
*
A295
frequency
2-step deceleration
A096
frequency
*2nd 2-step deceleration
*
A296
frequency
Related functions
* To switch to the 2nd control, allocate 08 (SET) to the multi-function input terminal and then turn it on.
•The acceleration/deceleration time can be switched via the multi-function input terminal or
automatically with an arbitrary frequency.
•To switch via the multi-function input terminal, allocate 09 (2CH) to it.
(Example 1) When A094/A294 is set to 00
FW
2CH
Acceleration 1
Output frequency
F002/F202
A092/A292
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
00: Switched via multi-function input 09
(2CH)
01: Switched by setting
00: Switched via multi-function input 09
(2CH)
01: Switched by setting
0.0 to 400
0.0 to 400
0.0 to 400
0.0 to 400
Acceleration 2
Deceleration 2
Deceleration 1
A093/A293 F003/F203
Data
F002, F003, F202, F203, C001 to C005
(Example 2) When A094/A294 is set to 01
FW
Acceleration 2
A095/A295
Acceleration 1
Output frequency
F002/F202
A092/A292
A093/A293 F003/F203
4-2 Function Mode
Default setting
Unit
15.0
s
15.0
s
15.0
s
15.0
s
00
00
0.0
Hz
0.0
Hz
0.0
Hz
0.0
Hz
Deceleration 2
A096/A296
Deceleration 1
4-24