Multi-function Output Terminal Contact Selection

This function allows you to set either contact for the two multi-function output terminals respectively.
Parameter No.
C031
C036
Specifications of the Multi-function Output Terminal P1
•Below are the specifications of the multi-function output terminal P1.
C031 set value
(NO contact)
(NC contact)
•The PC terminal acts as a common terminal at sink/source logics.
4-71
ON delay
Function name
Multi-function output
00: NO contact
terminal P1 contact
01: NC contact
selection
Relay output (MA, MB)
00: NO contact between MA and MC
contact selection
01: NC contact between MA and MC
Inside the Inverter
Power supply
ON
00
OFF
ON
01
OFF
OFF delay
ON delay
Data
P1
PC
Output status
ON
OFF
-
ON
OFF
-
OFF delay
Default setting
00
01
Electrical specifications
Between each terminal and PC
Voltage drop 4 V max. at power-on
Max. allowable voltage: 27 V DC
Max. allowable current: 50 mA