Hardware Monitor - Overland Storage SnapSAN S1000 User Manual

Servers
Hide thumbs Also See for SnapSAN S1000:
Table of Contents

Advertisement

SnapSAN S1000 User Guide

Hardware Monitor

The Hardware Monitor tab on the Enclosure Management screen shows the information of
current voltages and temperatures, and provides an Auto Shutdown option.
If Auto Shutdown is enabled, the system will shutdown automatically when the internal
power levels or temperature are not with normal levels. For better data protection, it is
recommended to check Auto Shutdown.
For better protection and avoiding single short period of high temperature that could trigger
an automatic shutdown, the system uses rules to gauge if a shutdown is needed. This is done
using several sensors placed on key systems that the system checks every 30 seconds for
preset temperatures:
• The core processor temperature limit is 80º C.
• The iSCSI NIC temperature limit is 65º C.
• The SAS expander and SAS controller temperature limits are 65º C.
When one of these sensors reports a temperature above the threshold for three (3)
continuous minutes, the system automatically shuts down. If a high temperature situation
doesn't last for at least three minutes, the system will not trigger a shutdown.
10400310-003 01/2013
©2010-13 Overland Storage, Inc.
Enclosure Management
4-33