7.4.6
Show Power Command
Use the SRM show power command to determine whether the failure of
a system running Tru64 UNIX or OpenVMS was related to a fan,
temperature, or power supply problem. You can use this command if
you are able to restart the system. Otherwise, invoke RMC and use the
env command.
Example 7–8 Show Power Command
P00>>> show power
Power Supply 0
Power Supply 1
Power Supply 2
System Fan 1
System Fan 2
System Fan 3
System Fan 4
System Fan 5
System Fan 6
CPU 0 Temperature
CPU 1 Temperature
CPU 2 Temperature
CPU 3 Temperature
Zone 0 Temperature
Zone 1 Temperature
Zone 2 Temperature
P00>>>
Power supplies. Power supply 2 is not installed.
System fans. Fan 3 is not working.
Temperature sensors on CPUs. CPU 0 is above threshold.
Temperature sensors on PCI backplane.
Status
Good
Good
Not Available
Good
Good
Bad
Good
Good
Good
Warning
Good
Good
Good
Good
Good
Good
Troubleshooting 7-17