WI777D 08/00
DIRECT ADDRESS PROGRAM MODE
This is an extension of the Dealer Program Mode. This method of programming is used in conjunction with the Keypad
Programming Worksheets that follow. Refer to these worksheets to identify the 4-digit location (address) of the feature to
be programmed. An illustrative example is provided on the next page.
DATA ENTRY
ADDRESS
LOCATIONS
LOCATIONS
LEFT DIGIT
3
0000
0000
HEXADECIMAL DATA:
TO
BLANK (•) = No Options
4093
1 to 9 = Entries 1 to 9
0 = Entry of 10
B to F = Entries 11 to 15
ACCESSING DIRECT ADDRESS PROGRAM MODE
1. Press EEEEEE A
2. Press g Until "ACTIVATE PROGRAM Y/N" (GEM-RP1CAe2),
"TURNON PROG Y/N" (GEM-RP2ASe2) or "17" (GEM-RP3DGTL) appears on the
keypad display.
3. Press F To Enter Dealer Program Mode
4. Press C To Exit Easy Menu Driven Program Mode
L
NAPCO Security Systems
KEYPAD PROGRAMMING OVERVIEW
Direct Address Programming allows you to go directly to the address
RIGHT DIGIT
locations and change the data entries to customize your control panel
C
options. Whereas the Easy Menu Program Mode is a simple quick
start guide with limited options, the Direct Address Program Mode is
more flexible allowing you to change all the options.
It consists of multiple address locations (up to 4093) with two data
entry locations each (left and right) as shown in the adjacent diagram.
Master Security Code
(printed on microprocessor can)
Dealer Security Code (Address 0500)
& Enter Direct Address Program Mode
or
X
GEM-P9600 Programming Instructions
!
Page 29
GEMINI
AI #ZN =08 #KP=1
SYSTEM ARMED
# OF ZONES IN AREA 1
A2 #ZN=00 #KP=0
01/01/97
12:00AM
ENTER # ZONES X X
NEXT/YES
A
1 2
3
E
D
PRIOR/NO
B
4
5 6
F
AREA
C
7 8 9 0
G
COMPUTERIZED SECURITY SYSTEM
R