WI1089 GEM-P801 Installation Instructions
1. Enter
A 8
2. Enter User 1 Code (
1 2 3 4
(Default)
J
3. Press
,
ARMED
STATUS AND HSYSTEM TROUBLE
LED's WILL FLASH
G E M I N I
1
H
A 1 is displayed indicating
User 1 Code is programmed
and 2-8 are blank.
Zone LED Meaning
User Arm/Disarm Code not programmed
OFF
User Arm/Code is currently being programmed
Flashing
User Arm/Disarm Code has been programmed
Steady
TABLE
5
Z
L
D
-U
ONE
ED
EFINITION
10
While in User Program Mode the Armed, Status
and
System Trouble LEDs will continue to
H
)
flash, follow the example below to program
User 2's code to 1923.
User Mode Programming Example:
1. Press
2. Enter
LED will continue to flash until the 4th digit
is entered. The keypad will beep 4 times
confirming a valid entry (Zone LED steady).
Deleting a User Code
.
Press the number of the User to be deleted, the
zone LED will be flashing indicating that the
user has been selected. Press the
the LED associated with the user will now be
OFF.
Exiting User Program Mode
To exit User Program Mode press the
key.

GEM-P801 Commands

User Commands
A 1
Enter this command to turn on the Bell, keypad
sounder and keypad LEDs for 2 seconds. The
battery is tested during a Bell Test, and
automatically every *24 hours to ensure proper
P
M
SER
ROGRAM
ODE
battery operation under load. The Alarm output
requires a battery in order to supply the
specified output. If the battery cannot sustain
, Zone 2 LED will Flash
2
, Zone 2
1 9 2 3
F
C
Bell Test
the load, a low battery indication will be
displayed. A battery test is also performed on
power-up after a 3 minute delay.
*A battery test occurs every 4 hours when
Household Fire [96-3] has been selected.
D Easy Arm
Press this key to arm the panel. To disarm the
panel a valid Arm/Disarm code must be entered.
Requires Easy Exit/Easy Arm [21-2] to be
enabled.
Interior
E
Enter this command to bypass all Exit/Entry
Follower Zones or Home/Away Zones (only if the
system is programmed exclusively for Home/
key,
Away with Delay zones).
Instant
F
Enter this command before or after arming to
remove the entry delay on Entry/Exit Zones. The
keypad ARMED LED will flicker rapidly. Faulting
a Exit/Entry Zone will result in an immediate
alarm.
Chime ON/OFF
A 5
Enter this command to turn chime ON/OFF. The
Keypad will chime on any zone that has not been
selected as an Exit/Entry Follower Zone, Home/
Away with Delay Zones, or 24 Hour Zone.
+ User 1 Code - User Program
A 8
Mode
Keypad Sleep Mode ON/OFF
A 9