KEYPAD DISPLAY FUNCTION MENU
FUNCTION
DISPLAY ZN FAULTS
DISPLAY ZN BYPASSED
DISPLAY ZN DIRECTORY
ACTIVATE BELL TEST
DISPLAY PHONE #'S
DISPLAY SYS TRBL
DISPLAY FIRE ALARM
DISPLAY FIRE TRBL
DISPLAY OP/CL
ACTIVATE OVERVIEW
ACTIVATE CHIME
ACTIVATE WATCH
RESET SYSTEM TRBL
RESET SENSOR MSG
START EXIT TIME
FAULT FIND
ACTIVATE LOCATE
EZM ZONE FIND
ACTIVATE DIALER TEST
DISPLAY ALARM LOG
DISPLAY TOTAL LOG
DISPLAY FIRE LOG
DISPLAY OP/CL LOG
DISPLAY SYSTEM LOG
AUTOARM IN 1-4HRS
DISPLAY AUTARM SCHD
ACTIVATE PROGRAM
ACTIVATE DOWNLOAD
DISPLY RF XMITTER STAT
RELAY CONTROL
J
!
Press
to save each code.
To proceed to the next User Code, set the cursor to the User Number and change it using the number buttons. Program a
new User Code as previously described. Press NEXT (
Example: Program a code of "2222" for user 02, with User Option of "User Program", User "Level 3" and Access Control Option "Keypad No. 1". Enter
"2222" for a user code, "2 3" for user option and "blank(•) 1" for access control option.
CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above
J
and press
to save. Similarly, to cancel a code, blank out each number of the code press
X
GEM-P9600 Programming Instructions
NOTES:
LEVEL*
*
Minimum Level required to access function
1
** Level-3 Code with appropriate user option
1
*** Requires Dealer Code
1
1
1
1
1
1
3
3**
1
2
3
3
1
***
***
***
3
3
3
3
3
3
2
3
3**
3
Related User Options: "Ambush Code" (Address 0495), "Panel Access Code" (Address
1
0490), "Dealer Security Code" (Address 0500) & "Enable User Code by Area" (Address
2500-2531).
1
OPTIONS
Disabled
User Code not active in this area.
Blocked View
Allows User Code to block another code from being viewed by another user.
An unblocked code cannot view a blocked code, but a blocked code can
view all codes. The master user code and the dealer program code can view
all codes.
User Program
User Program Option is enabled for Keypad 1 only, wherever it is connected
(any area). If enabled, Level 3 must also be enabled.
Bypass
Allows User Code to bypass zones.
Overview
This option, along with Level 3 Authorization, enables selection of
OVERVIEW mode at a keypad. This Mode provides a system status display
of all areas at a glance.
Arm Only
Prevents User Code from disarming this area.
Service
A Service Code has restricted arm/disarm rights; if an area is armed with a
SERVICE ON
Service Code, a "
on the GEM-RP1CAe2 keypad) and the area can be disarmed with any valid
User Code, including a Service Code. If the area is armed with OTHER than
a Service Code, it CANNOT be disarmed with a Service Code. This is
typically used to allow tradesmen access to premises under control of the
owner.
Access
This is normally used to activate a door striker while an area is disarmed. A
code with the access option will not function as an arm/disarm code. When
the code is entered, the keypad will display "
Wire on the keypad will become Active Low (Ground Potential) for 7
seconds.
) button to proceed.
E
USER OPTIONS
EXPLANATION
" appears on the GEM-RP2ASe2 keypad (a "
ENTER NOW
" and the Brown
J
to save.
L
NAPCO Security Systems
WI777D 08/00
S
"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gem-p9600