Gemini GEM-P9600 Programming Instructions Manual page 26

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P9600:
Table of Contents

Advertisement

!
Page 26
USER AUTHORITY LEVEL
KEYPAD DISPLAY FUNCTION MENU
FUNCTION
LEVEL*
DISPLAY ZN FAULTS
DISPLAY ZN BYPASSED
DISPLAY ZN DIRECTORY
ACTIVATE BELL TEST
DISPLAY PHONE #'S
DISPLAY SYS TRBL
DISPLAY FIRE ALARM
DISPLAY FIRE TRBL
DISPLAY OP/CL
ACTIVATE OVERVIEW
ACTIVATE CHIME
ACTIVATE WATCH
RESET SYSTEM TRBL
RESET SENSOR MSG
START EXIT TIME
FAULT FIND
ACTIVATE LOCATE
EZM ZONE FIND
ACTIVATE DIALER TEST
DISPLAY ALARM LOG
DISPLAY TOTAL LOG
DISPLAY FIRE LOG
DISPLAY OP/CL LOG
DISPLAY SYSTEM LOG
AUTOARM IN 1-4HRS
DISPLAY AUTARM SCHD
ACTIVATE PROGRAM
ACTIVATE DOWNLOAD
DISPLY RF XMITTER STAT
RELAY CONTROL
J
!
Press
to save each code.
To proceed to the next User Code, set the cursor to the User Number and change it using the number buttons. Program
a new User Code as previously described. Press NEXT (
Example: Program a code of "2222" for user 02, with User Option of "User Program", User "Level 3" and Access Control Option
"Keypad No. 1". Enter "2222" for a user code, "2 3" for user option and "blank(•) 1" for access control option.
CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above
J
and press
to save. Similarly, to cancel a code, blank out each number of the code press
X
GEM-P9600 Programming Instructions
NOTES:
*
Minimum Level required to access function
** Level-3 Code with appropriate user option
1
*** Requires Dealer Code
1
1
1
1
OPTIONS
1
Disabled
1
Blocked View
1
3
3**
1
User Program
2
Bypass
3
Overview
3
1
***
Arm Only
***
Service
***
3
3
3
3
Access
3
3
2
3
Related User Options: Ambush Code" (Address 0495), "Panel Access Code" (Address 0490),
3**
"Dealer Security Code" (Address 0500) & "Enable User Code by Area" (Address 2500-2531).
3
1
1
USER OPTIONS
EXPLANATION
User Code not active in this area.
Allows User Code to block another code from being viewed by another user.
An unblocked code cannot view a blocked code, but a blocked code can view
all codes. The master user code and the dealer program code can view all
codes.
User Program Option is enabled for Keypad 1 only, wherever it is connected
(any area). If enabled, Level 3 must also be enabled.
Allows User Code to bypass zones.
This option, along with Level 3 Authorization, enables selection of OVERVIEW
mode at a keypad. This Mode provides a system status display of all areas at a
glance.
Prevents User Code from disarming this area.
A Service Code has restricted arm/disarm rights; if an area is armed with a
SERVICE ON
Service Code, a "
" appears on the GEM-RP2ASe2 keypad (a "
the GEM-RP1CAe2 keypad) and the area can be disarmed with any valid User
Code, including a Service Code. If the area is armed with OTHER than a
Service Code, it CANNOT be disarmed with a Service Code. This is typically
used to allow tradesmen access to premises under control of the owner.
This is normally used to activate a door striker while an area is disarmed. A
code with the access option will not function as an arm/disarm code. When the
code is entered, the keypad will display "
the keypad will become Active Low (Ground Potential) for 7 seconds.
) button to proceed.
E
WI777D 08/00
ENTER NOW
" and the Brown Wire on
J
to save to save.
L
NAPCO Security Systems
S
" on

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gem-p9600

Table of Contents