SYSTEM OPTIONS (ADDRESS 2420-2422, 3874 & 3879-3881)
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Disable Keypad
1
Instant Button
Enable
2
Line-Fault Test
Disable AC Fail Detection
4
Telco Fail
8
only when Armed
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
Don't Clear Aux. Relay
1
with Arm/Disarm
Telco Answering
2
Service Overide
4
Disable Auto Status
Veri-phone Zones
8
trip Fire Output
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
1
Disable Area Entry Relays
Disable Exit/Entry Urgency
2
Tone at Keypad
Enable Burg. Output for
4
Keyfob Chirp
Enable Burg. Output on Telco
8
Fail only when Armed
LEFT DATA
SYSTEM OPTIONS
VALUES
(CIRCLE
1
Enable Set Time/Date
RESERVED
2
Enable
4
Time/Date Display
RESERVED
8
!
1. Select the desired option by circling
!
2. Add the data values (ex: 15=1+2+4+8) from the selected options.
!
3. Enter in address location (left and right digits).
NOTE: Dark shaded data value box shows option not available.
X
GEM-P9600 Programming Instructions
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
*
Note: If "Automatic Interior Bypass" in
Address 2421 is selected, then "Interior 1
Normally Bypassed" in Address 2419 must
also be selected.
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
"
)
LEFT DIGIT (SUM
OF DATA VALUES)
[Default = blank (•) blank (•)]
ALARM/TROUBLE
REPORTING CODES
Wireless Low Battery
Wireless Supervisory
Wireless Tamper
[Default = blank (•) blank (•) from address 3879-3881]
ADDRESS 2420
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2421
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 2422
RIGHT DIGIT (SUM
OF DATA VALUES)
ADDRESS 3874
RIGHT DIGIT (SUM
OF DATA VALUES)
"
the data values for each digit (left and right).
ADDRESS
3879-3881
LEFT
ADDR
RIGHT
blank (•)
3879
blank (•)
3880
blank (•)
3881
WI777D 08/00
RIGHT DATA
SYSTEM OPTIONS
VALUES
"
)
(CIRCLE
Disable System Trouble
1
Audible at Keypad
Chime on
2
E4 Lug
Disable Code required
4
for Func. Mode Lvl. 1
Disable Code required
8
for Easy Bypass
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
Automatic
1
Interior Bypass *
Veri-phone Zones trip
2
Aux. Relay
Veri-phone Zones Priority
4
over Alarms
Aux. Output Chirp on
8
Keyfob Arming
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
1
Fire Output Cadence
Wireless Smoke
2
Low Battery Resound
Supervised
4
Alarm Output
Enable Smoke Detector
8
Dirty Trouble
RIGHT DATA
VALUES
SYSTEM OPTIONS
"
)
(CIRCLE
1
Enable GEM-PRINT
Cancel Report
2
to Telco 3
Report Wireless Trouble
4
to Telco 1
Report Wireless Trouble
8
to Telco 3