KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-RP1CAe2, GEM-RP2ASe2 and GEM-RP3DGTL Keypads. If there is more than one
keypad in the system, only Keypad No. 1 may be used for programming.

KEYPAD INSTALLATION

Three types of keypads may be used with the GEM-P9600: the GEM-RP1CAe2, the GEM-RP2ASe2 and the GEM-RP3DGTL. Each
must be assigned an address number (1–7) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS,
which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-
area Commercial Burglary installation.
GEM-RP1CAe2 - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a PGM output.
A GEM-RP1CAe2 is recommended for use as Keypad #1.
GEM-RP2ASe2 - is a fixed English Alpha Symbol LCD keypad combining several preset LCD words with a limited message line.
NOTE: Due to space constraints, available messages are abbreviated and will scroll automatically.
GEM-RP3DGTL - is a Digital Display numeric keypad combining a dual seven segment display with LED indicators to convey system
status.

CONFIGURING THE KEYPADS

A total of up to 15 keypads may be connected to the panel. GEM-RP1CAe2, GEM-RP2ASe2 and GEM-RP3DGTL
keypads may be intermixed but require different configuration procedures, as described in the following paragraphs.
However, Keypads 8 - 15 may only be GEM-RP1CAe2 model.
Configuring the GEM-RP1CAe2 Keypad
Each GEM-RP1CAe2 keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c)
keypad address; (d) compatibility number; (e) EZM address; and (f) zone response.
To enter the GEM-RP1CAe2 Configuration Mode:
1. Move jumper JP5 (located at the upper-right corner of the control panel board) from Pins 1-2 (top two) to Pins
2-3 (bottom two). NOTE: See Wiring Diagram.
2. After about 15 seconds, the display will read "XX OUT OF SYSTEM", where XX indicates the keypad address.
3. Press
11123 A
KEYPAD BEEP
Entry Sounder
ENTRY SOUNDER
KEYPAD ADDRESS
To assign the keypad number, proceed as follows:
1. Enter the assigned keypad number 01–15, then press the
beep; an invalid number will be rejected by a long beep.
2. Press the
A
button to continue or press the
X
GEM-P9600 Installation Instructions
and proceed as follows. (Repeat the following procedure for all keypads.)
Keypad Tactile Beep
Upon entering the Keypad Configuration Mode, "KEYPAD BEEP ON" will be displayed,
indicating that the tactile beep, which sounds when any button is pressed, is on. To
ON
turn off the tactile beep, press the
on and off).
Press the
button to continue or press the
A
To turn off the keypad sounder during entry time, press the
will toggle the tactile beep on and off). Press the
ON
the
C
button to exit.
Keypad Address
If more than one keypad is installed, each must be assigned a unique
keypad address (that is, no two keypads may be numbered alike):
01
!
keypads must be numbered consecutively (missing numbers are not permitted)
!
only Keypad No. 1 may be used for programming.
J
button to save. A valid number will be acknowledged by a short
C
button to exit.
J
J
button (the
button will toggle the tactile beep
button to exit.
C
J
button (the
A
button to continue or press
L
NAPCO Security Systems
WI742C 08/00
GEMINI
SYSTEM ARMED
01/01/97 12:00AM
NEXT/YES
A
1 2
3
E
D
PRIOR/NO
B
4
5 6
F
AREA
C
7 8 9 0
G
COMPUTERIZED SECURITY SYSTEM
R
NORMAL
KEYPAD
CONFIGURE
J
button