Removal & Installation Procedure
1. Disconnect the negative(-) terminal from the battery.
2. Discharge refrigerant from the system.
Notice
By connecting a manifold gauge connection hose to High/
Low pressure line, discharge the refrigerant.
3. Disconnect the inlet and outlet pipes of receiver drier.
Notice
When installing, check the O-ring and apply the compressor
oil.
Installation Notice
Tightening Torque
4. Remove the bracket bolt and then remove the receiver drier.
Installation Notice
Tightening Torque
5. Installation should follow the removal procedure in the
reverse order.
MANUAL & SEMIAUTO-HVAC 7B/C-19
4 - 6 Nm
5 - 8 Nm