Op16 Output Expander - Texecom Premier 640 Installation Manual

Hide thumbs Also See for Premier 640:
Table of Contents

Advertisement

Premier 640 Installation Manual

OP16 Output Expander

Output Module Layout
Network
Terminals
NETWORK IN
Remote
Engineers
+ -
T
Keypad
Interface
BANK 1
1
2
Bank 1
3
1
2
3
4
Outputs
4
BANK 1
5
1 to 8
6
7
8
Tamper
Switch
Connecting Output Modules
Output modules are connected to the network terminals
located at the bottom of the control panel (see pages 13 & 14
for details).
Output Module Addressing
Each output module must be assigned a different address
using the DIL switches located in the centre of the PCB.
The table below shows the expander addressing:
Address
DIL 1
DIL 2
1
On or off
2
Off
3
Off
4
Off
5
On
6
Off
7
Off
8
On
!
In order for an output module to mimic zone expander
outputs, the output module must be addressed the
same as the zone expander that it is mimicking.
Any combination of addresses can be used on each
output module i.e. Bank 1 can be addressed to mimic
expander 3 and Bank 2 can be addressed to mimic
expander 8.
Bank 1 switch sets the address of the device that Bank
1 outputs 1 to 8 will mimic.
Bank 2 switch sets the address of the device that Bank
2 outputs 1 to 8 will mimic.
INS344
Aux 12V
and Tamper
Network
Output
Terminals
Aux 12V
NETWORK OUT
-
-
+
+
+ -
R
Tmp
T
R
BANK 2
1
1
2
Amp
Power
3
1
2
3
4
4
BANK 2
5
6
7
8
DIL 3
DIL 4
Off
Off
Off
On
Off
Off
Off
On
Off
Off
Off
On
Off
Off
On
On
Off
On
Off
On
On
Off
On
On
Output Module Numbering
The table below shows the output allocation when the output
modules are installed:
Address
1
2
3
4
5
Bank 2
6
Outputs
1 to 8
7
8
Outputs
Power LED
The output module has 16 programmable outputs, which can
be used to drive auxiliary devices such as LED's, sounders or
relays etc. Wire as per Panel Outputs shown on page 23 (see
page 60 for details). The electrical characteristics for the
outputs are shown below:
Bank
1
2
Tamper Output
The tamper switch on the output module is connected to the
tamper output at the top of the module. If monitoring of the lid
tamper is required, this output must be connected to a
suitable input on the control panel or zone expander.
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Outputs
(Network 1)
(Network 2) **
Expander 1, 1 - 8
Expander 1, 1 - 8
Expander 2, 1 - 8
Expander 2, 1 - 8
Expander 3, 1 - 8
Expander 3, 1 - 8
Expander 4, 1 - 8
Expander 4, 1 - 8
Expander 5, 1 - 8
Expander 5, 1 - 8
Expander 6, 1 - 8
Expander 6, 1 - 8
Expander 7, 1 - 8
Expander 7, 1 - 8
Expander 8, 1 - 8
Expander 8, 1 - 8
Outputs
Max Current
1 to 8
100mA
1 to 8
100mA
Installation
Outputs
Type
Switched -ve
Switched -ve