User Profile Text; User Options; User Options 1; User Options 2 - Texecom Premier 640 Installation Manual

Hide thumbs Also See for Premier 640:
Table of Contents

Advertisement

Premier 640 Installation Manual

User Profile Text

Each User Profile can be given a 16 character text name to
identify it. See page 33 for details of how to program text.

User Options

The user option menus define which options are available to
the users assigned to the User Profile when their code is
entered. There are 4 screens of user options, all are
programmed in the same way
3
Press
to edit options then either:
Press
%
to scroll through the options and press
to toggle the selected option on and off, or:.
3
use keys
!
-
*
'Star' = option is NOT selected).

User Options 1

A - Arming
Areas assigned to the selected user can be armed.
D - Disarming
Areas assigned to the selected user can be disarmed.
O - Omitting
Zones assigned to the same areas as the selected user can
be omitted, providing that they have the 'omit' attribute
assigned to them.
R - Eng. Reset (Engineers only)
Areas programmed as 'Engineer reset' can be reset after an
Alarm has occurred.
a - Local Arming
The User can only arm areas that the keypad is assigned to.
d - Local Disarm
The User can only disarm areas that the keypad is assigned to,
or areas that are in entry or alarm (provided that the code has
that area assigned to it).
Y - Auto 'YES'
After a User code has been entered, pressing the
confirm the next action is not required.
F - Disarm First
If an area is already armed and the selected user enters their
code, the 'Disarm' option is displayed.

User Options 2

U - User Menu
The selected user has access to the User menu. However,
the selected user will only have access to options assigned in

'User Options 3'.

E - Eng. Program (Engineers only)
Only Available to Engineers.
D - Dual Code
The selected user can only access an area when a second
User code (with the 'Dual Code' attribute and also assigned
to the same area) is entered. Dual Code users will also
activate the '1
st
and 2
nd
Code' output type.
INS344
('Letter' = option IS selected,
key to
0
V - Vacation
The selected user is enabled the first time it is used to disarm
the system and can be used as many times as required.
However, it will be automatically deleted the first time that the
User 01 code is used to disarm. Vacation users will only be
deleted by the Master user, once they have been used on the
system.
S - Door Strike
The selected user will activate any outputs programmed as
'Door Strike', whenever their codes are entered.
!
The 'Door Strike' output works independently of any
Access Profile assigned to the user.
R - Call Rem. PC
The selected user has access to the 'Call Remote PC' option,
allowing them to initiate a call to a remote upload/download
PC.
C - Duress Code
The selected user will activate any outputs programmed as
'Duress', whenever their codes are entered.
O - Open/Close
The selected user will report open (disarm) and close (arm)
events to an Alarm Receiving Centre every time they arm or
disarm.
User Options 3.
C - Change Code
The selected user can change their own User code.
Z - Chime Zones
The selected user can access the 'Edit Chime Zones' option,
allowing them to select which zones chime when activated.
T - Change Timers
The selected user can access the 'Override Timers', 'Alter
Timers', 'Alter Part Arms', 'Alter Hol. Dates' and 'Edit Phone
No.' menu options.
S - System Tests
The selected user can access the 'System Tests' option,
allowing them to walk test zones, activate the external
sounder etc..
U - Setup Users
The selected user can access the 'Setup Users' option,
allowing them to alter existing users or assign new users.
However, users cannot assign User types to the system that
have a higher access level than themselves. Also, if a user
assigns a Custom User type, functions that are not available
to them cannot be assigned to the Custom user.
E - Eng. Access
The selected user can access the 'Enable Engineer' option,
allowing them to authorise Engineer access or Remote UDL
access to the system.
A - Add Eng. Code (Engineers only)
Only Available to Engineers.
N - NVM Locking (Engineers only)
Only Available to Engineers.
Programming the Control Panel