Premier 640 Installation Manual
05 Global Bell Time
When all areas are armed, the system uses the 'Global Bell
Delay' and 'Global Bell Duration' timers (see page 47 for details).
Area Bell Time
When all areas are armed, the system uses the 'Area Bell
Delay' and 'Area Bell Duration' timers (see page 39 for details).
06 - 24Hr Omit Global
'24-Hour' type zones can be omitted from any keypad.
24Hr Omit Local
Only
keypads
assigned
'24-Hour' type zones can be used to omit the zone.
07 - Remove Omits
When zones have been 'Omitted' by a user, the zones will be
automatically reinstated by the system when the area they
are assigned to is next disarmed.
Leave Omits
When zones have been 'Omitted' by a user, the zones will
remain omitted until the user reinstates them.
08 - Override Com Dly
If an area is 'Fully' armed and an Intruder alarm occurs in that
area, Intruder alarm events (for that area) are reported to the
Alarm Receiving Centre immediately.
Enforce Com Dly
If an area is 'Fully' armed and an Intruder alarm occurs in that
area, Intruder alarm events (for that area) are reported to the
Alarm Receiving Centre after any programmed 'Coms delay'
has expired (see page 39 for details).
09 - NVM is Unlocked
The factory default settings can be reloaded by pressing the
Factory Restart button during power up.
NVM is Locked
The factory default settings cannot be reloaded by pressing
the factory default button during power up.
!
If the NVM is locked and the Engineer User code has
been lost or forgotten, the control panel will have to be
returned to Texecom to be unlocked.
10 - Engineer Only
Access to the Engineers Programming menus can be
obtained by just entering the Engineer User code.
User + Engineer
Access to the Engineers Programming mode can only be
obtained, if a User (with the 'Engineer Access' attribute) has
authorised engineer access (see page 86 for details).
11 - Chime Audible
Zones programmed with the 'Chime 2 or 3' attribute will only
generate a Chime tone.
Chime Visible (Default)
Zones programmed with the 'Chime 2 or 3' attribute will
generate a Chime tone. The keypad will also display the
number of the zone that was activated.
12 - Omit Tampers No
A user cannot omit Tamper faults on a zone.
Omit Tampers Yes
A user can omit Tamper faults on a zone.
INS344
to
the
same
area
as
13 - Offline Printing
If a printer is plugged onto the control panel, nothing will be
printed unless a printout is requested (see page 98 for
details).
Online Printing
If a printer is plugged onto the control panel, anything that is
logged in the event log is also printed at the same time.
14 - Hide Act. Fault
If a zone with the 'Activity' attribute is not activated during the
'Activity Delay' time window, the area that the zone is
the
assigned to can still be armed. However, this fault will be
indicated to the user when they try to arm the area.
View Act. Fault
If a zone with the 'Activity' attribute is not activated during the
'Activity Delay' time window, the area that the zone is
assigned to cannot be armed. This situation can only be
overcome by activating the zone.
15 - Hide Exit Errors
If a user tries to arm an area and there are zones activated,
the exit mode will continue (giving a visual and audible
indication that there is a problem).
View Exit Error
If a user tries to arm an area and there are zones activated,
the exit mode is suspended until all of the zones are secure.
16 - Enable Code Tampers
24 invalid key presses on a keypad will cause a Code Tamper
condition (see option 17).
No Code Tampers
A Code Tamper condition will never occur when the keys on
a keypad are pressed more than 24 times.
17 - Code Tamper Alarm
A Code Tamper condition will cause a Tamper alarm in the
areas that the keypad is assigned to.
Code Tamper Lockout
A Code Tamper condition will cause the keypad to lockout for
5 minutes.
18 - Areas A-H & I-P
The first 8 areas will be displayed as letters A through to H and
the last 8 areas will be displayed as letters I through to P.
Areas 1-8 & I-P
The
first
8
1 through to 8 and the last 8 areas will be displayed as letters
I through to P.
19 - Auto Area Select
When an Engineers code is entered to gain access to the
programming mode, ALL Zones and Tampers are disabled
i.e. if any Tampers, PA, Fire or Medical Alarms are activated -
NOTHING WILL HAPPEN.
Man. Area Select
When an Engineers code is entered to gain access to the
programming mode, the Engineer will have to select which
areas are going to be worked on.
!
Zones and Tampers are only disabled for the selected
areas all other areas will respond to zone activations
and tampers as normal.
Programming the Control Panel
areas
will
be
displayed
as
numbers
49