Programming the Control Panel

8XP Zone Expander

Expander Layout
Engineers
Tamper
Keypad
Interface
Switch
NETWORK IN
+ -
Remote
D
Zones
1 & 2
ON
1
Aux
12V
Zones
3 & 4
-
+
Aux
Input
YPE0123456
Com Port
Aux
Speaker
Input
Output
Connecting Expanders
Expanders are connected to the network terminals located at
the bottom of the control panel (see pages 13 & 14 for
details).
Expander Addressing
Each Expander must be assigned a different address using
the DIL switches located in the centre of the PCB. The table
below shows the expander addressing:
Address
DIL 1
DIL 2
1
On or off
2
Off
3
Off
4
Off
5
On
6
Off
7
Off
8
On
!
Never set two expanders on the same network to the
same address.
Expander Zones
The expander has eight programmable zones (see page 21
for wiring details). Each zone is also fully programmable (see
page 34 for details).
16
Network
Terminals
Power LED
NETWORK OUT
+ -
Tamper
T
R
T
R
Disable
S
Power
2 3 4
-
5
1
2
3
4
6
7
8
Spk
OUTPUTS
Address
Outputs
Switch
1 to 8
DIL 3
DIL 4
Off
Off
Off
On
Off
Off
Off
On
Off
Off
Off
On
Off
Off
On
On
Off
On
Off
On
On
Off
On
On
Zone Numbering
The table below shows the zone allocation when the
expanders are installed:
Address
1
2
3
4
5
6
Zones
5 & 6
7
8
Aux
12V
Expander Auxiliary Input
The expander has one programmable input. This auxiliary input
Zones
can be used to monitor auxiliary devices such as tamper loops
7 & 8
etc. Wire as per Aux Tamper shown on page 22 (see page 59
for details). The system will respond as follows:
Input Status
0V Applied
0V Removed
!
For further details on how the input status affects the
system please refer to page 59.
* For wiring details, see page 24.
Expander Outputs
The zone expander has eight programmable outputs, which
can be used to drive auxiliary devices such as LED's,
sounders or relays etc. Wire as per Panel Outputs shown on
page
23
(see
characteristics for the outputs are shown below:
Outputs
1 to 8
1
2
3
4
Expander Speaker Output
1
2
3
4
The expander has an output that can be used for driving up to
1
2
3
4
one 16Ω or two 8Ω loudspeakers (see page 22 for details).
1
2
3
4
1
2
3
4
Expander Com Port
The Com Port can be used to connect a PSU200 montored
1
2
3
4
power supply or a RadioPlus Inteligent Receiver.
1
2
3
4
1
2
3
4
Expander Lid Tamper
The lid tamper of each expander can be disabled if required
by fitting a jumper link across the centre and right hand pins
of the 'Enable Tamper' pins (JP2) leaving the left hand pin
free. These pins are located to the left of the address DIL
switch just beneath the fuse.
Premier 640 Installation Manual
Zones
(Network 1)
9 - 16
17 - 24
25 - 32
33 - 40
41 - 48
49 - 56
57 - 64
65 - 72
System Response
Input Secure
EOL
page
60
for
details).
Max Current
100mA
Zones
(Network 2)
73 - 80
81 - 88
89 - 96
97 - 104
105 - 112
113 - 120
121 - 128
129 - 136
Input Active
Various *
The
electrical
Type
Switched -ve
INS344