Specifications

Remote Keypads

Electrical
Operating Voltage
Current Consumption without
Prox
Quiescent (Not Backlit)
Alarm (Not Backlit)
Fully Backlit
Alarm + Fully Backlit
Current Consumption with Prox
Quiescent (Not Backlit)
Alarm (Not Backlit)
Fully Backlit
Alarm + Fully Backlit
Data Network
Keypad Type
Premier LCD
Premier LCDL
Premier LCDP
Premier LCDLP
Zones
Default EOL Resistor Values
EOL Resistor
Contact Resistor
Fault Resistor
0 - 1k
1k1 to 4k
4k1 to 5k6
5k7 to 8k
8k1 to 20k (30k)
21k+ (31k+)
Output
Back Lighting
Speaker Output (LCDL/LCDLP) Minimum load 8Ω
Speaker Volume (LCDL/LCDLP) Fully adjustable
Proximity Reader (LCDP/LCDLP) Tag
Environmental
Operating Temperature
Storage Temperature
Maximum Humidity
EMC Environment
Physical
Dimensions (W x H x D)
Packed Weight
102
10 - 13.7V
DC
25mA
45mA
100mA
145mA
85mA
105mA
185mA
205mA
4-wire standard 7/0.2
alarm cable up to 500m
Star, Daisy Chain or any
combination of the two
32 Character LCD
32 Character large LCD
LCD + Prox Reader
LCDL + Prox Reader
2
(Alternatives available)
2k2 (3k3)
4k7 (3k3)
2k2
Zone Short
Zone Secure
Zone Fault
Zone Active
Zone Mask
Zone Tamper
100mA switched to 0V
Fully adjustable
-10°C (+14°F) to
+55°C (+131°F)
-20°C (-4°F) to
+60°C (+140°F)
95% non-condensing
Residential
Commercial
Light Industrial
Industrial
145mm x 115mm x 30mm
260g Approx.

Zone Expanders

Electrical
Operating Voltage
Current Consumption 4XP 8XP
Quiescent
Alarm (Nothing Connected)
Data Network
Zones
Premier 4XP
Premier 8XP
Premier 60IXD
Default EOL Resistor Values
EOL Resistor
Contact Resistor
Fault Resistor
0 - 1k
1k1 to 4k
4k1 to 5k6
5k7 to 8k
8k1 to 20k (30k)
21k+ (31k+)
Outputs
Outputs 1 & 2 (4XP)
Outputs 1 - 8 (8XP)
Speaker Output (4XP & 8XP)
Environmental
Operating Temperature
Storage Temperature
Maximum Humidity
EMC Environment
Physical
Dimensions (W x H x D)
Packed Weight
Premier 640 Installation Manual
9 - 13.7V
DC
65mA
65mA
4-wire standard 7/0.2
alarm cable up to 500m
Star, Daisy Chain or any
combination of the two
4 DP or EOL zones
8 DP or EOL zones
60 iD zones (2 loops)
(Alternatives available)
2k2 (3k3)
4k7 (3k3)
2k2
Zone Short
Zone Secure
Zone Fault
Zone Active
Zone Mask
Zone Tamper
100mA switched to 0V
100mA switched to 0V
Minimum load 8Ω
-10°C (+14°F) to
+55°C (+131°F)
-20°C (-4°F) to
+60°C (+140°F)
95% non-condensing
Residential
Commercial
Light Industrial
Industrial
170mm x 140mm x 35mm
200g Approx.
INS344