Installation

OP16 Output Expander

A maximum of 1 output module can be connected to the
network along with keypads and zone expanders.
The Premier OP16 output module can be set up to mimic
the outputs of zone expanders.
!
In order for an output module to mimic zone
expander outputs, the output module must be
addressed the same as the zone expander that it is
mimicking.
Output Module Layout
Network
Terminals
Remote
NETWORK IN
Engineers
+ -
T
Keypad
Interface
BANK 1
1
2
Bank 1
3
1
2
3
4
Outputs
4
BANK 1
5
1 to 8
6
7
8
Tamper
Switch
Connecting Output Modules
Output modules are connected to the network terminals
located at the bottom left hand corner of the control panel
(see pages 13 & 14 for connection details).
20
Aux 12V
and Tamper
Network
Output
Terminals
Aux 12V
NETWORK OUT
-
-
+ -
+
+
R
T
R
Tmp
BANK 2
1
1
2
Amp
Power
3
1
2
3
4
4
BANK 2
5
6
7
8
Output Module Addressing
Each output module must be assigned a different address
using the DIL switches located in the centre of the PCB.
!
Bank 1 switch sets the address of the device that
Bank 1 outputs 1 to 8 will mimic.
!
Bank 2 switch sets the address of the device that
Bank 2 outputs 1 to 8 will mimic.
The table below shows the output module addressing:
Address
1
On or off
2
Output Module Numbering
The table below shows the output allocation when the
output modules are installed:
Address
Bank 2
1
Outputs
1 to 8
2
Outputs
The output module has 16 programmable outputs, which
Power LED
can be used to drive auxiliary devices such as LED's,
sounders or relays etc. Wire as per Panel Outputs shown on
page 24 (see page 53 for programming details). The
electrical characteristics for the outputs are shown below:
Bank
1
2
Tamper Output
The tamper switch on the output module is connected to the
tamper output at the top of the module. If monitoring of the
lid tamper is required, this output must be connected to a
suitable input on the control panel or zone expander.
Premier 24 Installation Manual
DIL 1
DIL 2
DIL 3
Off
Off
Off
On
Off
Outputs
Expander 1, 1 - 8
Expander 2, 1 - 8
Outputs
Max Current
1 to 8
100mA
1 to 8
100mA
DIL 4
Off
1
2
3
4
Off
1
2
3
4
Type
Switched -ve
Switched -ve
INS248