Programing the panel through keypad:
Press 1234 on the control panel. The below
message will be displayed.
Press 2 to reach "Area programming"
Press Yes
Press Down arrow button ( ) five times to select "Area Options"
Press Yes
Press 11 to reach "Confirmed Reset"
Press NO ( X ) to edit the option & Press 0 to disable all areas, then Press Yes
Press 13 to reach "Anti-code Reset"
Press NO ( X ) to edit the option & Press 0 to disable all areas, then Press Yes
Technical Support
Premier Elite Default setting
:
91520 10269
Elite Series panel
Elite 24
Elite 64-W
Elite 168
Elite 640
 :
indiatechsupport@texe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Premier Elite 24 and is the answer not in the manual?

Questions and answers

Summary of Contents for Texecom Premier Elite 24

  • Page 1 Premier Elite Default setting Programing the panel through keypad: Elite Series panel Press 1234 on the control panel. The below message will be displayed. Elite 24 Elite 64-W Elite 168 Press 2 to reach “Area programming” Elite 640 Press Yes Press Down arrow button ( ) five times to select “Area Options”...
  • Page 2 Press 14 to reach “ATS Path Faults” Press NO ( X ) to edit the option & Press 0 to enable all areas, then Press Yes Press 15 to reach “Arm with No ATS” Press NO ( X ) to edit the option & Press 0 to enable all areas, then Press Yes Press 16 to reach “AC Mains Fail”...
  • Page 3 Press 18 to reach “Full Arm Coms” Press NO ( X ) to edit the option & Press 0 to enable all areas, then Press Yes Press 19 to reach “Part Arm Coms” Press NO ( X ) to edit the option & Press 0 to enable all areas, then Press Yes Press 20 to reach “Unarm Fire Coms”...
  • Page 4 Press NO ( X ) to edit the option & Press 0 to enable all areas, then Press Yes Press Menu ( ) two times Press 3 to reach “Global Options” Press Yes Press Down arrow button ( ) one time to select “System Config.” Press Yes Press 10 to reach “User + Engineer”...
  • Page 5 Press 20 to reach “Predictive Text” Press NO ( X ) to change it to “Manual Text Edit” Press 31 to reach “Clock = 50Hz” Press NO ( X ) to change it to “Clock = Crystal” Press 34 to reach “EN50131 Enabled” Press NO ( X ) to change it to “EN50131 Disabled”...
  • Page 6 Press Menu ( ) three times on the control panel and then press Yes to logoff from your control panel If there are any ‘System Alerts’, press 5678 and press Reset button to clear the alerts. Your system is now set up. Technical Support ...