Remote Keypads - Texecom Premier 640 Installation Manual

Hide thumbs Also See for Premier 640:
Table of Contents

Advertisement

Premier 640 Installation Manual

Remote Keypads

Keypad Layout
Tamper
Speaker
Switch
Output
Address
On
Switch
1
2
3
4
Connecting Keypads
Keypads are connected to the network terminals located at
the bottom of the control panel (see pages 13 & 14 for
details).
Keypad Addressing
Each keypad must be assigned a different address using the
DIL switches located on the left hand side of the PCB. The
table below shows the keypad addressing:
Address
DIL 1
DIL 2
1
On or off
2
Off
3
Off
4
Off
5
On
6
Off
7
Off
8
On
Engineers
On
!
Never set two keypads on the same network to the
same address.
When using a keypad as an Engineer's keypad, the
DIL switches must all be 'On'.
Keypad Zones
The keypad has two programmable zones (see page 21 for
details). Each zone is also fully programmable (see page 34
for details).
INS344
Output
Network
Terminals
+
-
T
R
SPK
O/P
NETWORK
DIL 3
DIL 4
Off
Off
Off
On
Off
Off
Off
On
Off
Off
Off
On
Off
Off
On
On
Off
On
Off
On
On
Off
On
On
On
On
On
Keypad Output
The remote keypad has one programmable output, which
can be used to drive auxiliary devices such as LED's,
sounders or relays etc. Wire as per Panel Outputs shown on
page
23
(see
characteristics for the output are shown below:
Output
1
Piezo
Sounder
Keypad Speaker Output (LCDL/LCDLP Only)
The Premier LCDL and Premier LCDLP keypads have an
output that can be used for driving up to one 16Ω or two 8Ω
Zones
loudspeakers (see page 22 for details).
!
The speaker volume is also fully adjustable (see page
57 for details).
Programmable 'Info.' LED
The 'Info.' LED on the front of the keypad can be
programmed to mimic the keypad output or show the armed
status of an area (see page 57 for details).
Adjustable Backlighting
To adjust the keypad backlighting press the YES key for 5
seconds, then with the YES key still pressed use
increase or decrease the backlighting until the required
brightness is achieved, then release both keys.
!
The backlight can only be adjusted when the keypad is
not in a menu.
1
2
3
4
1
2
3
4
Keypad Lid Tamper
1
2
3
4
The lid tamper of each keypad can be disabled if required
1
2
3
4
using the relevant keypad option in the Keypad Setup menu
1
2
3
4
(see page 57 for details).
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
page
60
for
details).
Max Current
100mA
Switched -ve
Installation
The
electrical
Type
%
to
15

Hide quick links:

Advertisement

Table of Contents
loading