Programming the Control Panel
Do Bell Test
>73!:0!3$-$6:Z[
78958$$)!\:5-<
Yes
78958$$)!\:5-<
T5$J!74$8:!?09
2
abc
78958$$)!\:5-<
C0!N$--!"$<:
Yes
I#<K!>73!:0!:$<:
N$--!5<!!!!!WHBB
Omit
I#<K!>73!:0!:$<:
N$--!C5<(E-$D
I#<K!>73!:0!:$<:
C595!W!!MMMMMMMM
3
def
I#<K!>73!:0!:$<:
C595!W!!MMMMMMMM
3
def
I#<K!>73!:0!:$<:
C595!W!!MMMMMMMM
Menu
This option allows Allows the Bell, Speaker and various
control panel outputs to be tested.
The following outputs can be individually tested:
Test Bell
The Bell output
Test Strobe
The Strobe output
Test Speaker
The Speaker output
Test Digi
The Hardwired digicom outputs
Test Panel
The panel outputs
Test RedCARE
The plug on RedCARE outputs
Test Com????
The plug on digi outputs
LCD Display
The LCD keypad display
User Outputs
Any outputs that have the 'User Test'
attribute (see page 66 for details).
!
Pressing OMIT at the Bell or Strobe Test will cause the
Strobe output to pulse 3 times, invoking Engineers
Hold Off mode if a Texecom bell box is connected.
94
Press OMIT to invoke the
Engineers Hold Off mode
of a Texecom Bellbox
Use the SCROLL key to
select the required test
Press YES to test ALL
channels or use keys 0 - 8
to select individual channels
e.g. 3 = Channel 3
Press YES again to clear ALL
channels or use keys 0 - 8
to clear individual channels
e.g. 3 = Channel 3
Do Walk Test
YES to Select:-
Engineer Utils
Yes
Engineer Utils
View Event Log
1
Engineer Utils
Do walk test
Yes
Walk test Areas>
* * Area 01 * *
Walk test Areas>
* * Area 01 * *
Yes
* NONE *
Chime
Zone 005
Lounge PIR
Area
Zones that need
testing are :
???
Zone 001
>007
Front Door
Menu
Any of the zones on the system can be walk tested to ensure
that they operate correctly. A walk test can only be performed
when the system or area is disarmed.
!
Once a zone has been activated it will not generate a
chime tone again. If however the
zone will chime every time it is activated.
The Walk test menu also includes a last activation log that
can be recalled when doing a walk test. This log shows zones
that have NOT been activated over a period of days.
Pressing the
key will firstly show the zones that still need
6
testing, pressing the
6
zones that have not been activated that day, to view zones
that have not been activated for 3 days, type in 003 the
maximum number of days that can be recalled is 255,
pressing the
key a third time will revert back to the
6
standard walk test display.
Premier 640 Installation Manual
U
Use
Key or enter the
Area number to walk test
Press YES to walk test
Press CHIME to select:
Chime Once then lockout zone
Chime on every activation
or
No Chime at all
Press AREA. to toggle the
display between the zones
that have been tested and
the zones that still need testing
To view zones that have not
activated recently, e
nter the
number of days required
i.e. 007 will show zones that have
not activated in the last 7 days
key is pressed, a
2
key a second time will display the
INS344