Texecom Premier 640 Installation Manual page 10

Hide thumbs Also See for Premier 640:
Table of Contents

Advertisement

Installation
Control Panel PCB Layout
1
2
F2
L/M
Kick
Start
R/R
3
15
DC+
DC -
1
2
21
3
4
V
4
1
Expansion
00mA = 1 Amp
5
Load
Defaults
6
7
18
8
Fault
Tx
Rx
F4
F6
5
Engineer
Remote
-
+
T
R
NETWORK
1
1: AC Input
Connected to the 16.5V transformer.
DO NOT CONNECT THE MAINS SUPPLY TO THE AC
INPUT TERMINALS ON THE PCB.
2: Battery Connections
A 12V rechargeable battery must be connected to these
terminals in order to provide continuous system operation in
the event of an AC Mains failure (see page 12 for details).
3: Digicom Power & Inputs
These terminals provide unfused power; remote reset and line
fault inputs and are normally used for connecting a stand-alone
communicator to the control panel (see page 23 for details).
4: Digicom Outputs
Outputs 1 to 8 are low current (100mA '-ve' applied) and
would normally be used when connecting a stand-alone
communicator to the control panel (see page 23 for details).
Each output is fully programmable (see page 61 for details).
5: Engineers Keypad
A portable Engineers keypad can be plugged on here to
allow easier access for programming and testing.
!
When using a keypad as an Engineers keypad, the
address must be set to '10' (see page 15 for details).
The keypad zones and lid tamper are not monitored.
6: Network Data Connections
Networks provide connection for the keypads and zone
expanders. The '+' and '–' terminals provide power whilst
the 'T' transmits data and 'R' receives data (see page 13 for
details).
7: Auxiliary 12V Power
These terminals are for connecting devices that require 12V
power (protected by a 1A fuse).
8: External Sounder Connections
These terminals are used for connecting to an external
sounder unit (see page 22 for details).
10
F1
14
F3
Com 1
16
Com 2
19
Heartbeat
20
Fault
Tx
Rx
Fault
Tx
Rx
F7
F8
-
-
+
+
T
R
T
R
NETWORK 2
NETWORK 3
16
13
Com 3
Box
Tamp
17
Fault
Tx
Rx
Fault
Tx
Rx
Fault
F9
F10
-
-
+
+
+
T
R
T
R
NETWORK 4
NETWORK 5
NETWORK 6
6
9: Auxiliary Tamper Connections
These terminals can be used for monitoring the tamper loop of
an auxiliary device (see page 21 for details).
10: Loudspeaker Connections
These terminals can be used for connecting up to one 16Ω
or two 8Ω loudspeakers (see page 22 for details).
11: Panel Outputs
Outputs 1 & 2 are 500mA '-ve' applied, outputs 3 & 4 are
500mA '+ve' applied and output 5 is a clean contact relay
(see page 23 for wiring details). These outputs are all fully
programmable (see page 60 for details).
12: Plug-on Communicator Connections
This socket provides connection for Premier plug-on
communicator (see page 25 for details).
13: Box Tamper Connection
The box tamper micro switch is connected here. The micro
switch provides tamper protection for the main control panel in
case of unauthorised access. To disable the box tamper,
remove the micro switch lead and fit a jumper link across the
two pins.
14: Plug-on RedCARE/Dualcom Connections
These pins provide connections for a plug-on RedCARE,
Dualcom, Digicom or RM8 Relay module. Each output is fully
programmable (see page 61 for details).
!
When a device is plugged on to these pins, not all
outputs may be available, please refer to the relevant
documentation for details.
15: Battery Kick-start Button
When powering up the panel without AC Mains present, this
button must be pressed in order to connect the battery.
!
If AC Mains is present this button does not need to be
pressed.
Premier 640 Installation Manual
12
14
22
Tx
Rx
Fault
Tx
Rx
Fault
Tx
F11
F12
-
-
-
+
+
T
R
T
R
NETWORK 7
NETWORK 8
11
OP4+
OP3+
OP2-
OP1-
7
Spk
-
10
Spk+
Aux
9
Tamp
+12v
Bell
8
Tamp
F5
0v
Rx
Strb
F13
T
R
Bell/Spk
Aux12V
Fault
Fault
INS344

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents