Plug-On Communicators - Texecom Premier 640 Installation Manual

Hide thumbs Also See for Premier 640:
Table of Contents

Advertisement

Premier 640 Installation Manual

Plug-on Communicators

The
Com300
is
a
communicator/300-baud modem for use with a standard
analogue telephone line.
The
Com2400
is
a
communicator/2400-baud modem for use with a standard
analogue telephone line in addition, this modem can also send
Short Message Service (SMS) text messages to a mobile
phone.
The
ComISDN
is
a
communicator/modem for use with an ISDN telephone line.
These Communicators can be used to report system events to
an Alarm Receiving Centre using Fast Format, Contact ID or
SIA Level II or to upload/download control panel information
using the Wintex UDL software and a PC.
Plugging on the Communicator
Ensure that the board is the correct way up (see below).
Locate the plug into the communicator socket on the control
panel and line up the mounting holes with the pillars in the
base. Once all the holes line up, press down gently until the
pillars snap into the holes.
Box
Tamp
Top Right Hand Corner
INS344
multi
format
8-channel
multi
format
8-channel
multi
format
8-channel
Premier 640
Control Panel
Standard Telephone Line Connections
A standard telephone line must be connected to the Com300
digital
or Com2400 communicator as shown below:
Master
digital
Socket
digital
Com300
or
Com2400
ISDN Telephone Line Connections
An ISDN telephone line must be connected to the ComISDN
communicator as shown below:
T
R
T1
R1
!
For details on testing the communicators, see page 67.
OP4+
OP3+
OP2-
OP1-
-
Spk
6
5
4
T = 5 or A - White/Blue ring
3
R = 2 or B - Blue/White ring
2
1
Telephone cable
Type 1/0.5mm CW1308
This terminal must be connected to
the incoming AC Mains earth supply
T
R
T1
To other telephone
extension sockets
R1
ISDN
Terminal
RJ45
Lead
ComISDN
Installation
25