Xp Zone Expander; Iprox Module - Texecom Premier 640 Installation Manual

Hide thumbs Also See for Premier 640:
Table of Contents

Advertisement

Premier 640 Installation Manual

4 XP Zone Expander

Expander Layout
Outputs 1&2
Engineers Keypad
Interface
Network IN
Terminals
NETWORK IN
2-
Engineers Keypad
+ -
T
R
O/P O/P
JP1
D
S
JP2
Zones
1 & 2
ON
1
2 3 4
Aux 12V
Zones
1 & 2
Connecting Expanders
Expanders are connected to the network terminals located at
the bottom of the control panel (see pages 13 & 14 for
details).
Addressing
4XP expanders are addressed as one or (normally) two
keypads on the network. Each 4XP has to have a unique
address, which must not conflict with any keypad or any
other 4XP on the same network.
The following table shows the expander addresses & the
keypad slots that each would occupy.
Address D I L 1 D I L 2 D I L 3 D I L 4 Keypads
1
On
2
off
3
off
4
off
5
On
6
off
7
off
8
On
Zones
The 4XP provides 4 alarm zones, 2 for each of the 2 keypad
slots it occupies. Each zone is fully programmable (see page
5.1 Zone Setup34) and has to be mapped to the system (see
Keypad Zone Mapping page 57).
Outputs
2 Programmable outputs are provided 1 for each of the 2
keypad slots occupied by the expander (see page 60 for
output programming)
INS344
Loud Speaker Terminals
Network OUT
Terminals
1-
NETWORK OUT
+ -
T
R
SPK+ SPK-
Tamper Switch
Power LED
Address Switch
JP4
Com Port
off
off
off
On
off
off
off
On
off
off
off
On
off
off
On
On
off
On
off
On
On
off
On
On
Expander Speaker Output
One speaker output is provided for connecting one external
16Ω or 2 8Ω loudspeakers (see page 22 for details).
The speaker volume is programmed through the keypad setup
menu (see page 57)
!
The speaker is available on keypad 1 of the two
keypad slots the 4XP occupies. (ie if the 4XP address is
5, the speaker will programmed as belonging to
keypad 5).
Expander Com Port
The Com Port can be used to connect a RadioPlus
Inteligent Receiver.

iProx Module

iProx Layout
Extension
Loudspeaker
Terminals
Wiegand
Interface
D0
Connections
D1
Network
Terminals
T
R
Connection
The iProx Module is connected to the network terminals
located at the bottom of the control panel (see pages 13 &
14 for details).
Addressing
The iProx Module is addressed as a keypad and will occupy
1 & 2
a keypad slot on the network. The unit must have a unique
address, which must not conflict with keypad or any other
2 & 3
iProx Module on the same network
3 & 4
The following table shows the addressing:
4 & 5
5 & 6
Address D I L 1 D I L 2 D I L 3 D I L 4
6 & 7
1
7 & 8
2
8
3
4
5
6
7
8
Refer to the iProx Module manual for programming and
operating instructions.
Option & Address Switches
Options
Address
SW1
SW2
Tamper
Internal
Off
Sounder
JP1
PIP0123456
Com1
For Future Use
On
off
off
off
On
off
off
off
On
off
off
off
On
off
off
off
On
off
off
off
On
On
off
On
Installation
Volume Adjustment
For Speaker
Com
Door Strike
N/O
Relay
N/C
Request to
RTE
Exit Input
JP5
L+
Int
L2-
Remote
Ext
Prox Coil
L1-
Connections
Int
C2
Ext
JP4
C1
off
off
off
On
On
On
On
On
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents