The plug-on communicator can be programmed to dial up to
3 sets of Alarm Receiving Centre (ARC) information. Each 'Set'
consists of the following options:
Protocol
This is the reporting protocol that is used to communicate
with the Alarm Receiving Centre. The following 4 protocols
are supported:
Fast Format: The panel will report using Fast Format. If
this option is selected the 'Reporting Channels' must be
programmed (see below)
Contact ID: The panel will report using Contact ID. If this
option is selected, the 'Reporting Areas' must be
programmed (see below)
SIA Level II: The panel will report using SIA Level II
EasyCom Pager: The panel will report to an EasyCom
type pager
SMS Messaging: The panel will send Short Message
Service (SMS) text messages to a mobile phone
Primary Telephone Number
This is the first telephone number that the communicator will
dial for the Alarm Receiving Centre or the first mobile
telephone number to send SMS to. Each telephone number
can be up to 24 digits.
Secondary Telephone Number
This is the second telephone number that the communicator
will dial for the Alarm Receiving Centre or the second mobile
telephone number to send SMS to. Each telephone number
can be up to 24 digits.
Account Number
This is the account number that will be reported to the Alarm
Receiving Centre. Each account number can be up to 6 digits.
!
Each area can also have its own account number (see
page 71 for details).
Dialling Attempts
This is the number of times the communicator will try to dial the
Alarm Receiving Centre or Pager telephone number.
!
The number of dialling attempts is limited to 9. If this value
is set to 0, the communicator will never dial out.
The following option is only displayed if the
Fast Format protocol is selected
Reporting on
This option defines which channels report to the selected
Alarm Receiving Centre.
Restoring on
This option defines which channels report a restore to the
selected Alarm Receiving Centre.
Open/Close on
This option defines which channels report Open/Close to the
selected Alarm Receiving Centre.
The following option is only displayed if Contact ID
or SIA Level II protocols are selected
Reporting Areas
This option defines which areas report events to the
selected Alarm Receiving Centre.
70
The following option is only displayed if Contact ID,
SIA Level II or EasyCom Pager protocols are selected
Reports
This option defines which events report to the Alarm
Receiving Centre when using Contact ID or SIA Level II.
P - Priority Alarm and Cancel Events
The system will report Priority alarm and cancel events to
the selected Alarm Receiving Centre.
A - Normal Alarm and Cancel Events
The system will report alarm and cancel events to the
selected Alarm Receiving Centre.
O - Open and Close Events
The system will report open and close events to the
selected Alarm Receiving Centre.
B - Omit and Reinstate Events
The system will report omit and reinstate events to the
selected Alarm Receiving Centre.
M - Maintenance Alarm Events
The system will report maintenance alarm events to the
selected Alarm Receiving Centre.
T - Tamper Alarm Events
The system will report tamper alarm events to the
selected Alarm Receiving Centre.
C - Test Call Events
The system will report test call events to the selected
Alarm Receiving Centre.
R - Restore Events
The system will report restore events to the selected
Alarm Receiving Centre.
The following option is only displayed if Fast Format
Contact ID or SIA Level II protocols are selected
Config.
This option defines which secondary options are enabled.
A - Area Account
Events are reported to the Alarm Receiving Centre using
the area account numbers (see page 71 for details).
S - SIA Level I / UCP
Events are reported to the Alarm Receiving Centre using
SIA Level I or or to an SMS Messaging Server using UCP.
R - Enable Radio-Pad
The system will use the Paknet radio-pad to report events
to the selected Alarm Receiving Centre.
G - Enable GSM Module
The system will use the GSM Module to report events to
the selected Alarm Receiving Centre.
A - AV Module
The AV Module will dial the Alarm Receiving Centre.
F - Use GSM First
The GSM module is the primary path when this is enabled
I - Connect Via IP
The system will use the IP Module to report events to the
selected Alarm Receiving Centre.
T - Send SIA Text
Text is sent to the Alarm Receiving Centre when using
SIA II (this makes the protocol SIA III)