Output Group - Area - Texecom Premier 640 Installation Manual

Hide thumbs Also See for Premier 640:
Table of Contents

Advertisement

Premier 640 Installation Manual
47 - Detector Test
This output type is activated via remote maintenance software
to initiate a diagnostics check on a PD6662: 2004/EN 50131-1
Grade 3 detector and deactivates after 10 seconds.
48 - ATS Remote Test
This output type conforms to the BSIA Form 175 Specification.
When a Line Fault is not present it can be activated remotely by
Wintex, or by using the 'Test Call Timer' or 'Start Test Call' option
on the control panel to initiate a test on ATE equipment that have
an ATS test input. NOTE: Only the RedCare Line Fault and
Control panel Line Fault inputs can be used with the output type.
49 - No ATS Available
This output type activates when no Alarm Transmission paths
are available and deactivates when the fault is cleared.
50 - CIE Fault
This output type activates when a fault occurs on the CIE and
deactivates when the fault is cleared.
51 - PSU Fuse Blown
This output type activates when the Auxiliary input type 'PSU
Monitor' detects a 12V failure and deactivates when the fault
is reset.
52 - PSU Battery Flt
This output type activates when the Auxiliary input type 'PSU
Monitor' detects a battery fault and deactivates when the fault
is reset.
53 – WD Test Active
This output is activated via remote maintenance software to
initiate a diagnostics check on an external sounder with
remote test capability and will deactivate after 1 minute.

Output Group - Area

Any Area Profile can be assigned to each output type. All
areas assigned to the area Profile will activate the output.
Select an output type from the following options:
00 - Alarm
This output type activates when any type of Intruder alarm occurs in
the selected area, and deactivates when the Intruder alarm is reset.
01 - Guard Alarm
This output type activates when a zone programmed as
'Guard' causes an Intruder alarm in the selected area and
deactivates when the alarm is reset.
02 - Guard Access Alarm
This output type activates when a zone programmed as
'Guard Access' causes an Intruder alarm in the selected area
and deactivates when the alarm is reset.
03 - Entry Alarm
This output type activates when a zone programmed as
'Entry/Exit 1 or 2' causes an Intruder alarm in the selected
area and deactivates when the alarm is reset.
04 - Confirmed Alarm
If an area is already in alarm, this output type activates when a
different zone (not on the entry route) is activated in the selected
area and deactivates at the end of the 'Confirmation' time, when a
code is entered within the 'Abort' time or when the alarm is reset.
05 - 24Hr Audible
This output type activates when a zone programmed as '24Hr
Audible' causes an Internal alarm or Intruder alarm in the
selected area and deactivates when the alarm is reset.
06 - 24Hr Silent
This output type activates when a zone programmed as '24Hr
Silent' causes a silent alarm or Intruder alarm in the selected
area and deactivates when the alarm is reset.
INS344
07 - 24Hr Gas
This output type activates when a zone programmed as '24Hr
Gas' causes a Silent alarm or Intruder alarm in the selected
area and deactivates when the alarm is reset.
08 - PA Alarm
This output type activates when any type of 'PA alarm' i.e. PA
audible, PA silent or Duress causes a PA alarm in the
selected area and deactivates when the alarm is reset.
09 - PA Silent
This output type activates when a zone programmed as 'PA
Silent' or a keypad PA (1 & 3) causes a silent PA alarm in the
selected area and deactivates when the alarm is reset.
10 - Duress
This output type activates when a User code with the 'Duress'
attribute causes a silent PA alarm in the selected area and
deactivates when the alarm is reset.
11 - Fire Alarm
This output type activates when a zone programmed as 'Fire'
or a keypad Fire (4 & 6) causes a Fire alarm in the selected
area and deactivates when the alarm is reset.
12 - Medical
This output type activates when a zone programmed as 'Medical'
or a keypad Medical (7 & 9) causes a Medical alarm in the
selected area and deactivates when the alarm is reset.
13 - Auxiliary Alarm
This output type activates when a zone programmed as
'Auxiliary' causes a Silent alarm in the selected area and
deactivates when the alarm is reset.
14 - Tamper Alarm
This output type activates when any type of Tamper alarm
occurs in the selected area and deactivates when the alarm is
reset.
15 - Alarm Abort
If the selected area is in alarm, this output type activates
when a User code is entered to cancel the alarm in the
selected area and deactivates after 10 seconds.
16 - Ready
This output type activates when all zones in the selected area
are secure and deactivates when any zone in the selected
area is activated.
17 - Entry Mode
This output type activates when the selected area is in the entry
mode and deactivates when the area is not in the entry mode.
18 - 2
nd
Entry Mode
This output type activates when the 2
selected area starts and deactivates when the 2
expires.
19 - Exit Mode
This output type activates when the selected area is in the exit
mode and deactivates when the area is not in the exit mode.
20 - Entry/Exit Mode
This output type activates when the selected area is in the
entry or exit mode and deactivates when the area is no longer
in the entry or exit mode.
21 - Armed
This output type activates when the selected area is armed
and deactivates when the selected area is disarmed.
22 - Full Armed
This output type activates when the selected area is fully armed
and deactivates when the selected area is disarmed.
Programming the Control Panel
nd
entry timer for the
nd
entry timer
63