Texecom Premier 640 Installation Manual page 93

Hide thumbs Also See for Premier 640:
Table of Contents

Advertisement

Premier 640 Installation Manual
Log Event
MANUAL TEST CALL
MIC ## TESTED
No RF Signal ###
Panel Line Fault
PART Armed
PART 1 Armed
PART 2 Armed
PART 3 Armed
POWERED UP
PROG. END
PROG. START
PSUac ## Alarm
PSUbat## Alarm
PSUvol## Alarm
PSUTam## Alarm
QUICK Armed
R/Bat ## Alarm
Radio Jammed
RADIO PAD LOST
REARM LOCK ###
RECENT Armed
Redcare Line Fault
REMOTE Armed
REMOTE Disarmed
Remote PC Reset
Remote Reset
Redcare Reset
RKP #,# MEDICAL
RKP #.# FIRE
RKP #,# AUD PA
RKP #,# SIL PA
RKP #,# Tamper
RKP #,# LOST
RKP LOCKED #,#
TAG ##
TESTED ###
TEST FAIL ###)
TIME Armed
TIME CHANGED
TIME Disarmed
TUBE ### Alarm
USER ##
USER CODE CHANGED
USER CODE DELETED
User Reset
WALK Tst start
Zone ### Alarm
Zone ### Tamper
Zone ### Restore
Zone ### Omitted
Zone ### Un-Omit
Zone ### Test Start
Zone ### Test End
INS344
A Manual test call has been initiated
Microphone ## on the Audio Verification Module has been tested
The Wireless receiver has detected a signal loss from zone ###
The control panel line fault input has been activated
Area ? has been Part Armed
Part Arm 1 has been selected
Part Arm 2 has been selected
Part Arm 3 has been selected
System Power Up (without doing a factory restart)
The Engineer has logged out of the Programming menu
An Engineer code has been entered
An expander input programmed as PSU Monitor control panel has detected an AC Mains failure
An expander input programmed as PSU Monitor control panel has detected a Battery fault
An expander input programmed as PSU Monitor control panel has detected a 12V Output failure
An expander input programmed as PSU Monitor control panel has detected a Tamper condition
Quick Arm from keypad #,#
The Wireless receiver has detected a low battery signal from device ##
The Wireless receiver has detected an attempt to jam its radio signal
The Radio-Pad has no signal or has lost communications with the control panel
Zone ### has locked out after reaching its re-arm limit (after causing an alarm)
Area ? has been armed recently
The Redcare has detected a line fault
Area ? was armed using the Wintex UDL software
Area ? was disarmed using the Wintex UDL software
A reset has been performed by the remote download PC
A reset has been performed using the 'Remote Reset' input
A reset has been performed by the Redcare
A Medical alarm (7 & 9) has occurred from keypad number #,#
A Fire alarm (4 & 6) has occurred from keypad number #,#
An Audible PA alarm (1 & 3) has occurred from keypad number #,#
A Silent PA alarm (1 & 3) has occurred from keypad number #,#
The cover of keypad #,# has been removed
Keypad ## has been lost from the network
Keypad #,# has been locked out from too many invalid key presses
User ## has presented their Prox TAG
Zone ### has been tested
Zone ### has failed its Soak test
Area ? was armed automatically using one of the control timers
The control panel Date has been changed
Area ? was disarmed automatically using one of the control timers
Zone ### (programmed as Tube Key) has caused an alarm
User ## has entered their code
A User code has been altered or added
A User code has been deleted
A reset has been performed using a User code
The Walk Test mode has been initiated
Zone ### has been activated
Zone ### has caused a Tamper alarm
Zone ### has restored to its normal condition
Zone ### has been omitted
Zone ### has been reinstated
Zone ### has been put on test
Zone ### has been removed from test
Programming the Control Panel
Description
93

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents