Attributes for Moment or Latch Keys

Select attributes by pressing keys 1 to 8 (a letter on the
display means the attribute is selected, a Dot on the display
means the attribute is not selected).
The following attributes are only available for 'Moment Key' or
'Latch Key' zone types.
I - INSTANT ARM
When using a key switch, the area will arm instantly.
P - PART ARMING
When using a key switch, the area will 'Part' arm.
F – FULL ARM DISABLE
When using a key switch to 'Full' arm an area, the key switch
is disabled once the area is armed.
D - DISARM ONLY
The key switch cannot be used for 'Arming' (it can only be
used for 'Disarming').
F - SILENTARMING
When arming using a key switch, the selected areas will arm
silently.
T - TIME ARM DISABLE
Activation of the key switch will override the 'Time Arming'
feature on the control panel and prevent it from operating
until the zone is reinstated.
K - KEY TUBE
A key switch zone type with this attribute will log when the
zone is activated and also when the zone is restored.

Attributes for Custom Zones

Select attributes by pressing keys 1 to 8 (a letter on the
display means the attribute is selected, a Dot on the display
means the attribute is not selected).
The following attributes are only available for 'Custom' zone
types.
I - INTERNAL
Activation of this zone (when armed) will cause the internal
sounders to activate.
B - BELL/STROBE
Activation of this zone (when armed) will cause the external
sounder/strobe to activate.
M - MONITOR 24Hr
The zone is armed at all times.
C - ENABLE COMS
Activation of this zone (when armed) will cause the area
'Alarm' output to activate.
!
Any Custom zone with this attribute will activate both
the internal and external sounders even if they are not
enabled above.
W - WARNING REQ.
If the zone remains Active for the duration of the 'Warning
Delay' timer (see page 48), a warning tone will occur every 30
seconds for 3 minutes (or until a code is entered or
pressed).
!
If MONITOR 24Hr is enabled, an internal alarm will
occur after the Warning Delay.
INS344

Zone Areas

The Premier 640 provides 80 Area Profiles. Each zone can be
allocated to an Area Profile which will determine which area(s) it
is assigned to.
See page 46 for Area Profile programming.
!
If a zone is assigned to an Area Profile that contains
more than one area, it will only be recognised by the
system when all areas it is assigned to, are armed.

Zone Text

Each zone can have up to 32 characters of descriptive text
assigned to it. Text is programmed in a similar way to mobile
phones. Select characters by pressing the corresponding key
the appropriate number of times (to select a character on the
same key, press
For a more information, see page 33.
The control panel also features Predictive text. This can be
used to make inserting words easier, i.e. when spelling the
word PIR, instead of typing 7444777, all that you need to do
is type 747 and the word is automatically selected.
!
This feature can be turned off if required by pressing
the
1
every time text mode is entered.

Zone Chime

Each zone can be programmed to chime the internal sounders
using one of the available chime tones when activated.

Remote Test Enable

Any zone with this attribute will be tested when the remote
test function is initiated from Wintex. Any detector on a zone
with the remote test attribute will be expected to go into alarm
during the remote test, if it does not go into alarm, the
detector will be reported as faulty.
!
This facility is only to be used in conjunction with
system output type 47 'Detector Test' see page 63.