Programming the Control Panel
25 - Log Part Omits
Areas assigned to 'Log Part Omits' respond as follows:
When an assigned area is part armed, all the zones that
are omitted for that area are logged in the event log
Areas not assigned to 'Log Part Omit' will never log the zones
that are omitted in the event log when the area is part armed.
26 - Multi Knock Area
Areas assigned to 'Multi Knock Area' will respond as follows:
Zones with the 'Double Knock' attribute will use the
multiple knock value set up in system options for zone
activations (see page 51 for details)
Areas not assigned to 'Multi Knock Area' will use the standard
2 knocks for zone activations.
For the 'Multi Knock Area' feature to work, the zone must be
programmed with the 'Double Knock' attribute (see page 36
for details).
27 - UDL Keypad
Areas assigned to 'UDL Keypad' can be controlled i.e. armed,
disarmed, reset etc. from the 'On Line Keypad' when using
the Wintex software and a PC.
Areas not assigned to 'UDL Keypad' cannot be controlled i.e.
armed, disarmed, reset etc. from the 'On Line Keypad' when
using the Wintex software and a PC.
28 - Auto Chime (C2A)
Areas assigned to 'Auto Chime' will respond as follows:
Zones assigned to the selected areas that have been
programmed for 'Chime' will only chime when 'Custom
Output 1, Stage A' is on
Areas not assigned to 'Auto Chime' will only chime when
chime for that area is manually enabled by the user.
DD 243 Options
To comply with DD 243, during the normal entry delay, the
control panel must prevent a Confirmed Intruder Alarm from
being reported to the Alarm Receiving Centre.
If a Portable ACE i.e. Electronic Keyswitch, Key Fob, Tag, Swipe
Card etc is being used for disarming, it is permissible for the
Confirmed Intruder Alarm signal to be re-enabled after the entry
delay has expired.
The following two options have been provided to ensure that
the control panel can be programmed to comply with this
standard if required.
WARNING
Owing to the ability to disable ALL of the
confirmation facilities, the customer should be
advised in writing by the alarm company that ALL
means of alarm confirmation are disabled when the
initial entry door is opened. The alarm company
should then obtain written acceptance from the
customer of the disabling of the means of alarm
confirmation.
44
29 - Confirm in Entry
Areas assigned to 'Confirm in Entry' will respond as follows:
If the entry mode is started for the selected area and a
Confirmed Intruder alarm occurs in that area, Confirmed
Intruder alarm events (for that area) are reported to the
Alarm Receiving Centre
Areas not assigned to 'Confirm in Entry' will never report
Confirmed Intruder alarm events to the Alarm Receiving
Centre during the entry mode.
!
To comply with DD 243, areas must NOT be assigned
to this option, thus preventing Confirmed Intruder
Alarms from being reported to the Alarm Receiving
Centre during the entry mode.
30 - Conf. after Entry
Areas assigned to 'Conf. After Entry' will respond as follows:
Alarm confirmation is ONLY disabled for the duration of the
Entry Time and is RE-ENABLED once the Entry Time has
expired, after which activation of a further two zones that are
not on the entry route must occur before the Alarm
Confirmation output will activate
Areas not assigned to 'Conf. After Entry' will never report
Confirmed Intruder alarm events to the Alarm Receiving
Centre after the entry delay has expired.
!
To comply with DD 243, areas must NOT be assigned
to this option, thus preventing Confirmed Intruder
Alarms from being reported to the Alarm Receiving
Centre after the entry delay has expired.
If a Portable ACE i.e. Electronic Keyswitch, Key fob, Tag,
Swipe Card etc. is used to disarm the system, it is
permissible for the Confirmed Intruder Alarm signal to
be re-enabled after the entry delay has expired. In this
case, areas CAN be assigned to 'Conf. After Entry'.
31 - Part Arm Enabled
Areas assigned to 'Part Arm Enabled' can be Part Armed.
Areas not assigned to 'Part Arm Enabled' cannot be Part
Armed.
32 - Bell Squawk
Areas assigned to 'Bell Squawk' will respond as follows:
When all of the assigned areas are fully armed, the bell will
activate once for 2 seconds, when any one of the assigned
areas are disarmed, the bell will activate twice for 2 seconds
and when any one of the assigned areas are disarmed
following an alarm, the bell will activate five times for 2
seconds.
Areas not assigned to 'Bell Squawk' will not activate the Bell
output when arming or disarming.
33 - FOB After Entry
Areas assigned to 'FOB After Entry' can only be disarmed
with a Radio FOB once the Entry procedure has been started.
Areas not assigned to 'FOB After Entry' can be disarmed with
a Radio FOB at any time.