4Xp Zone Expander; Iprox Module - Texecom Premier 24 Installation Manual

Texecom premier 24 installation manual
Hide thumbs Also See for Premier 24:
Table of Contents

Advertisement

Installation

4XP Zone Expander

Expander Layout
Outputs 1&2
Engineers Keypad
Interface
Network IN
Terminals
NETWORK IN
2-
+ -
Engineers Keypad
T
R
O/P O/P
JP1
D
S
JP2
Zones
1 & 2
ON
1
2 3 4
Aux 12V
Zones
1 & 2
Connecting Expanders
Expanders are connected to the network terminals located at
the bottom of the control panel (see pages 13 & 14 for
details).
Addressing
4XP expanders are addressed as one or (normally) two
keypads on the network. Each 4XP has to have a unique
address, which must not conflict with any keypad or any
other 4XP on the same network.
The following table shows the expander addresses & the
keypad slots that each would occupy.
Address D I L 1 D I L 2 D I L 3 D I L 4 Keypads
1
On
2
off
3
off
4
off
Zones
The 4XP provides 4 alarm zones, 2 for each of the 2 keypad
slots it occupies. Each zone is fully programmable (see page
35) and has to be mapped to the system (see page 51).
Outputs
2 Programmable outputs are provided 1 for each of the 2
keypad slots occupied by the expander (see page 54 for
output programming)
16
Loud Speaker Terminals
Network OUT
Terminals
NETWORK OUT
1-
+ -
T
R
SPK+ SPK-
Tamper Switch
Power LED
Address Switch
JP4
Com Port
off
off
off
On
off
off
off
On
off
off
off
On
4 (2 Zones)
Expander Speaker Output
One speaker output is provided for connecting one external
16Ω or 2 8Ω loudspeakers (see page 22 for details).
The speaker volume is programmed through the keypad setup
menu (see page 51)
!
The speaker is available on keypad 1 of the two
keypad slots the 4XP occupies. (ie if the 4XP address is
3, the speaker will programmed as belonging to
keypad 3).
Expander Com Port
The Com Port can be used to connect a RadioPlus
Inteligent Receiver.

iProx Module

iProx Layout
Tamper
Speaker
Terminals
Wiegand
Interface
Connections
Network
Terminals
Connection
The iProx Module is connected to the network terminals
located at the bottom of the control panel (see pages 13 &
14 for details).
1 & 2
Addressing
The iProx Module is addressed as a keypad and will occupy
2 & 3
a keypad slot on the network. The unit must have a unique
3 & 4
address, which must not conflict with keypad or any other
iProx Module on the same network
The following table shows the addressing:
Address D I L 1 D I L 2 D I L 3 D I L 4
1
2
3
4
Refer to the iProx Module manual for programming and
operating instructions.
Premier 24 Installation Manual
Option & Address Switches
Internal Sounder
Off
On
ON
1
2 3 4
Address
ON
1
2 3 4
Options
PIP0123456
Speaker
Volume Adj
On
off
off
off
off
On
off
off
off
off
On
off
off
off
off
On
Door Strike
Relay
Request to
Exit Input
Remote
Prox Coil
Connections
INS248